Literature DB >> 21996323

A viscosity-dependent affinity sensor for continuous monitoring of glucose in biological fluids.

Christophe Boss1, Eric Meurville, Jean-Michel Sallese, Peter Ryser.   

Abstract

We present a viscometric affinity biosensor for continuous monitoring of glucose in biological fluids such as blood and plasma. The sensing principle of this chemico-mechanical sensor is based upon the viscosity variation of a sensitive fluid with glucose concentration. Basically, this device includes both an actuating and a sensing piezoelectric diaphragms as well as a flow-resistive microchannel. In order to confine the sensitive fluid and allow glucose diffusion into the sensor, a free-standing alumina nanoporous membrane is also used as size-selective interface. Measurements carried out at nominal temperatures of 25 and 37 °C reveal that this sensor topology exhibits a high resolution in the current range of physiological blood glucose concentrations, i.e. 2-20 mM. In addition, complete reversibility was also demonstrated for at least 3 days. Finally, measurements performed in human blood serum confirm that this sensor fulfils all basic requirements for a use in continuous glucose monitoring of biological fluids.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21996323     DOI: 10.1016/j.bios.2011.09.016

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  6 in total

1.  A MEMS differential viscometric sensor for affinity glucose detection in continuous glucose monitoring.

Authors:  Xian Huang; Siqi Li; Erin Davis; Charles Leduc; Yann Ravussin; Haogang Cai; Bing Song; Dachao Li; Domenico Accili; Rudolph Leibel; Qian Wang; Qiao Lin
Journal:  J Micromech Microeng       Date:  2013-05       Impact factor: 1.881

2.  A MEMS Dielectric Affinity Glucose Biosensor.

Authors:  Xian Huang; Siqi Li; Erin Davis; Dachao Li; Qian Wang; Qiao Lin
Journal:  J Microelectromech Syst       Date:  2013-06-20       Impact factor: 2.417

3.  A differential dielectric affinity glucose sensor.

Authors:  Xian Huang; Charles Leduc; Yann Ravussin; Siqi Li; Erin Davis; Bing Song; Dachao Li; Kexin Xu; Domenico Accili; Qian Wang; Rudolph Leibel; Qiao Lin
Journal:  Lab Chip       Date:  2013-11-13       Impact factor: 6.799

4.  Micro-Electromechanical Affinity Sensor for the Monitoring of Glucose in Bioprocess Media.

Authors:  Lorenz Theuer; Micha Lehmann; Stefan Junne; Peter Neubauer; Mario Birkholz
Journal:  Int J Mol Sci       Date:  2017-06-08       Impact factor: 5.923

5.  Design and Fabrication of a BiCMOS Dielectric Sensor for Viscosity Measurements: A Possible Solution for Early Detection of COPD.

Authors:  Pouya Soltani Zarrin; Farabi Ibne Jamal; Subhajit Guha; Jan Wessel; Dietmar Kissinger; Christian Wenger
Journal:  Biosensors (Basel)       Date:  2018-08-21

6.  High Resolution Viscosity Measurement by Thermal Noise Detection.

Authors:  Felipe Aguilar Sandoval; Manuel Sepúlveda; Ludovic Bellon; Francisco Melo
Journal:  Sensors (Basel)       Date:  2015-11-03       Impact factor: 3.576

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.