Literature DB >> 21996214

Disturbances of kidney graft perfusion as indicators of acute renal vein thrombosis in contrast-enhanced ultrasonography.

P Grzelak1, I Kurnatowska, M Sapieha, M Nowicki, J Strzelczyk, M E Nowicki, L Stefańczyk.   

Abstract

INTRODUCTION: The aim of this study was to evaluate the usefulness of contrast-enhanced ultrasound (US-CE) to diagnose acute renal vein thrombosis (ARVT), acute rejection episodes (ARE), or acute tubular necrosis (ATN) in kidney grafts.
MATERIALS AND METHODS: We analyzed 171 US-CE among kidney transplantation patients in the early postoperative period. Patients underwent US-CE following a standard diagnostic protocol including real-time ultrasound (B-mode) and color Doppler ultrasound with spectral flow analysis. Tissue perfusion was analyzed based upon time-intensity curves for two regions: the renal cortex and the renal pyramids.
RESULTS: Of 14 patients, in whom standard ultrasound showed high resistance parameters in the renal artery, three showed ARVT and 11 had ATN or ARE, which were confirmed by biopsy. Among patients with ARVT, the US-CE showed a lack of contrast perfusion into the cortex and renal pyramids. Patients with ARE/ATN showed slower contrast inflow into the parenchyma with reduced but still present perfusion. The differences in mean signal intensity values were significant for both the cortex and the renal pyramids: cortex: -53.8±5.4 dB versus -35.0±3.5 dB (P<.05) and pyramids: -54.8±5.4 dB versus -37.0±3.5 dB (P<.05).
CONCLUSION: US-CE is a noninvasive method that provides easy, reliable differentiation of ARVT from ARE/ATN.
Copyright © 2011 Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21996214     DOI: 10.1016/j.transproceed.2011.08.067

Source DB:  PubMed          Journal:  Transplant Proc        ISSN: 0041-1345            Impact factor:   1.066


  2 in total

Review 1.  Contrast-enhanced ultrasound of transplant organs - liver and kidney - in children.

Authors:  Doris Franke; Reza J Daugherty; Damjana Ključevšek; Aikaterini Ntoulia; Vasileios Rafailidis; Marcelo S Takahashi; Alvaro Torres; Bernarda Viteri; Frank M Volberg
Journal:  Pediatr Radiol       Date:  2021-05-12

2.  Standard B presentation vs. contrast-enhanced ultrasound (US-CE). A comparison of usefulness of different ultrasonographic techniques in the evaluation of the echo structure and size of haematomas inpost-renal transplant patients: A preliminary report.

Authors:  Piotr Grzelak; Ilona Kurnatowska; Michał Nowicki; Janusz Strzelczyk; Michał Sapieha; Michał Podgórski; Magdalena Marchwicka-Wasiak; Ludomir Stefańczyk
Journal:  Pol J Radiol       Date:  2012-07
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.