Literature DB >> 21995929

Performance evaluation of the Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA, a 4th generation HIV assay for the simultaneous detection of HIV p24 antigen and antibodies to HIV-1 (groups M and O) and HIV-2 in human serum or plasma.

Christopher Bentsen1, Lisa McLaughlin, Elizabeth Mitchell, Carol Ferrera, Sally Liska, Robert Myers, Sheila Peel, Paul Swenson, Stephane Gadelle, M Kathleen Shriver.   

Abstract

BACKGROUND: A multi-center study was conducted to evaluate the Bio-Rad GS HIV Combo Ag/Ab EIA, a 4th generation HIV-1/HIV-2 assay for the simultaneous detection of HIV p24 antigen and antibodies to HIV-1 (groups M and O) and HIV-2 in human serum or plasma in adult and pediatric populations.
OBJECTIVES: The objectives of the study were to assess assay performance for the detection of acute HIV infections; sensitivity in known HIV positive samples; percent agreement with HIV status; specificity in low and high risk individuals of unknown HIV status; and to compare assay performance to a 3rd generation HIV assay. STUDY
DESIGN: The evaluation included testing 9150 samples at four U.S. clinical trial sites, using three kit lots. Unlinked samples were from routine testing, repositories or purchased from vendors.
RESULTS: GS HIV Combo Ag/Ab EIA detection in samples from individuals in two separate populations with acute HIV infection was 95.2% (20/21) and 86.4% (38/44). Sensitivity was 100% (1603/1603) in known antibody positive [HIV-1 Groups M and O, and HIV-2] samples. HIV p24 antigen detection was 100% (53/53) in HIV-1 culture supernatants. HIV-1 seroconversion panel detection improved by a range of 0-20 days compared to a 3rd generation HIV test. Specificity was 99.9% (5989/5996) in low risk, 99.9% (959/960) in high risk and 100% (100/100) in pediatric populations.
CONCLUSION: The GS HIV Combo Ag/Ab EIA significantly reduced the diagnostic window when compared to the 3rd generation screening assay, enabling earlier diagnosis of HIV infection. The performance parameters of the Bio-Rad GS HIV Combo Ag/Ab EIA are well suited for use in HIV diagnostic settings.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21995929     DOI: 10.1016/j.jcv.2011.09.023

Source DB:  PubMed          Journal:  J Clin Virol        ISSN: 1386-6532            Impact factor:   3.168


  9 in total

Review 1.  Human Immunodeficiency Virus Diagnostic Testing: 30 Years of Evolution.

Authors:  Thomas S Alexander
Journal:  Clin Vaccine Immunol       Date:  2016-04-04

2.  Acute infections, cost and time to reporting of HIV test results in three U.S. State Public Health Laboratories.

Authors:  Muazzam Nasrullah; Laura G Wesolowski; Steven F Ethridge; Kevin Cranston; Michael Pentella; Robert A Myers; James T Rudrik; Angela B Hutchinson; Spencer B Bennett; Barbara G Werner
Journal:  J Infect       Date:  2016-05-26       Impact factor: 6.072

3.  Performance of the fourth-generation Bio-Rad GS HIV Combo Ag/Ab enzyme immunoassay for diagnosis of HIV infection in Southern Africa.

Authors:  Estelle Piwowar-Manning; Jessica M Fogel; Paul Richardson; Shauna Wolf; William Clarke; Mark A Marzinke; Agnès Fiamma; Deborah Donnell; Michal Kulich; Jessie K K Mbwambo; Linda Richter; Glenda Gray; Michael Sweat; Thomas J Coates; Susan H Eshleman
Journal:  J Clin Virol       Date:  2014-11-27       Impact factor: 3.168

4.  Rapid Versus Laboratory-Based Testing for HIV and Hepatitis C at a Drug Detoxification Treatment Center: A Randomized Trial.

Authors:  Sabrina A Assoumou; Samantha M Paniagua; Benjamin P Linas; Jianing Wang; Jeffrey H Samet; Jonathan Hall; Laura F White; Curt G Beckwith
Journal:  J Infect Dis       Date:  2020-09-02       Impact factor: 5.226

5.  The cost-effectiveness of repeat HIV testing during pregnancy in a resource-limited setting.

Authors:  Lena H Kim; Deborah L Cohan; Teresa N Sparks; Rachel A Pilliod; Emmanuel Arinaitwe; Aaron B Caughey
Journal:  J Acquir Immune Defic Syndr       Date:  2013-06-01       Impact factor: 3.731

6.  Performance of a fourth-generation HIV screening assay and an alternative HIV diagnostic testing algorithm.

Authors:  Muazzam Nasrullah; Laura G Wesolowski; William A Meyer; S Michele Owen; Silvina Masciotra; Craig Vorwald; William J Becker; Bernard M Branson
Journal:  AIDS       Date:  2013-03-13       Impact factor: 4.177

Review 7.  Past, present and future molecular diagnosis and characterization of human immunodeficiency virus infections.

Authors:  Yi-Wei Tang; Chin-Yih Ou
Journal:  Emerg Microbes Infect       Date:  2012-08-22       Impact factor: 7.163

8.  Characterization of Humoral Immune Responses against Capsid Protein p24 and Transmembrane Glycoprotein gp41 of Human Immunodeficiency Virus Type 1 in China.

Authors:  Xiufen Li; Yue Wu; Xuqi Ren; Shuyun Deng; Guifang Hu; Shouyi Yu; Shixing Tang
Journal:  PLoS One       Date:  2016-11-01       Impact factor: 3.240

Review 9.  Point of Care Technologies for HIV.

Authors:  Mohan Kumar Haleyur Giri Setty; Indira K Hewlett
Journal:  AIDS Res Treat       Date:  2014-01-21
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.