Abstract

Fundamental research on non-spectroscopic interferences, also known as matrix effects, in inductively coupled plasma (ICP) mass spectrometry with sample introduction using nebulization is critically and exclusively examined in this review, starting with fundamental processes that may be a source of matrix effects during sample introduction, ion generation in the ICP, ion extraction through the interface, and ion transport through the ion optics to the detector. Various methods for attenuating matrix effects are then reviewed and illustrated with some examples. Instead of exhaustively reviewing the literature, representative references are used to comprehensively describe the main issues, several of which are also common to ICP optical emission spectrometry.
Copyright © 2011 Elsevier B.V. All rights reserved.

Year:  2011        PMID: 21995912     DOI: 10.1016/j.aca.2011.08.027

Source DB:  PubMed          Journal:  Anal Chim Acta        ISSN: 0003-2670            Impact factor:   6.558


  8 in total

1.  Development and characterization of reference materials for trace element analysis of keratinized matrices.

Authors:  Mina W Tehrani; Karl X Yang; Patrick J Parsons
Journal:  Anal Bioanal Chem       Date:  2020-02-04       Impact factor: 4.142

Review 2.  Quantitative aspects of inductively coupled plasma mass spectrometry.

Authors:  Ewa Bulska; Barbara Wagner
Journal:  Philos Trans A Math Phys Eng Sci       Date:  2016-10-28       Impact factor: 4.226

3.  An evaluation of M2+ interference correction approaches associated with As and Se in ICP-MS using a multi-day dataset along with ICP-MS/MS/HR-ICP-MS based analysis and hierarchical modeling as a means of assessing bias in fortified drinking waters and single component matrices.

Authors:  Skyler W Smith; Roy W Martin; Nicole Hanks; Patricia A Creed; Kasey Kovalcik; Robert A Wilson; Kevin Kubachka; Judith A Brisbin; Julio A Landero Figueroa; John T Creed
Journal:  J Anal At Spectrom       Date:  2022-03-18       Impact factor: 4.351

Review 4.  Living in a transient world: ICP-MS reinvented via time-resolved analysis for monitoring single events.

Authors:  M Resano; M Aramendía; E García-Ruiz; A Bazo; E Bolea-Fernandez; F Vanhaecke
Journal:  Chem Sci       Date:  2022-03-14       Impact factor: 9.969

5.  Online microdroplet calibration for accurate nanoparticle quantification in organic matrices.

Authors:  Stasia Harycki; Alexander Gundlach-Graham
Journal:  Anal Bioanal Chem       Date:  2022-05-18       Impact factor: 4.478

6.  Redox Speciation of Vanadium in Estuarine Waters Using Improved Methodology Based on Anion Exchange Chromatography Coupled to HR ICP-MS System.

Authors:  Lucija Knežević; Dario Omanović; Niko Bačić; Jelena Mandić; Elvira Bura-Nakić
Journal:  Molecules       Date:  2021-04-22       Impact factor: 4.411

7.  Recent advances in quantitative LA-ICP-MS analysis: challenges and solutions in the life sciences and environmental chemistry.

Authors:  Andreas Limbeck; Patrick Galler; Maximilian Bonta; Gerald Bauer; Winfried Nischkauer; Frank Vanhaecke
Journal:  Anal Bioanal Chem       Date:  2015-07-14       Impact factor: 4.142

Review 8.  Trends towards Effective Analysis of Fluorinated Compounds Using Inductively Coupled Plasma Mass Spectrometry (ICP-MS).

Authors:  Ruth Lorivi Moirana; Thomas Kivevele; Josephine Mkunda; Kelvin Mtei; Revocatus Machunda
Journal:  J Anal Methods Chem       Date:  2021-02-02       Impact factor: 2.193

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.