Literature DB >> 21993140

Novel LTCC-potentiometric microfluidic device for biparametric analysis of organic compounds carrying plastic antibodies as ionophores: application to sulfamethoxazole and trimethoprim.

S A A Almeida1, E Arasa, M Puyol, C S Martinez-Cisneros, J Alonso-Chamarro, M C B S M Montenegro, M G F Sales.   

Abstract

Monitoring organic environmental contaminants is of crucial importance to ensure public health. This requires simple, portable and robust devices to carry out on-site analysis. For this purpose, a low-temperature co-fired ceramics (LTCC) microfluidic potentiometric device (LTCC/μPOT) was developed for the first time for an organic compound: sulfamethoxazole (SMX). Sensory materials relied on newly designed plastic antibodies. Sol-gel, self-assembling monolayer and molecular-imprinting techniques were merged for this purpose. Silica beads were amine-modified and linked to SMX via glutaraldehyde modification. Condensation polymerization was conducted around SMX to fill the vacant spaces. SMX was removed after, leaving behind imprinted sites of complementary shape. The obtained particles were used as ionophores in plasticized PVC membranes. The most suitable membrane composition was selected in steady-state assays. Its suitability to flow analysis was verified in flow-injection studies with regular tubular electrodes. The LTCC/μPOT device integrated a bidimensional mixer, an embedded reference electrode based on Ag/AgCl and an Ag-based contact screen-printed under a micromachined cavity of 600 μm depth. The sensing membranes were deposited over this contact and acted as indicating electrodes. Under optimum conditions, the SMX sensor displayed slopes of about -58.7 mV/decade in a range from 12.7 to 250 μg/mL, providing a detection limit of 3.85 μg/mL and a sampling throughput of 36 samples/h with a reagent consumption of 3.3 mL per sample. The system was adjusted later to multiple analyte detection by including a second potentiometric cell on the LTCC/μPOT device. No additional reference electrode was required. This concept was applied to Trimethoprim (TMP), always administered concomitantly with sulphonamide drugs, and tested in fish-farming waters. The biparametric microanalyzer displayed Nernstian behaviour, with average slopes -54.7 (SMX) and +57.8 (TMP) mV/decade. To demonstrate the microanalyzer capabilities for real applications, it was successfully applied to single and simultaneous determination of SMX and TMP in aquaculture waters.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21993140     DOI: 10.1016/j.bios.2011.09.011

Source DB:  PubMed          Journal:  Biosens Bioelectron        ISSN: 0956-5663            Impact factor:   10.618


  3 in total

Review 1.  Opportunities and Challenges for Biosensors and Nanoscale Analytical Tools for Pandemics: COVID-19.

Authors:  Nikhil Bhalla; Yuwei Pan; Zhugen Yang; Amir Farokh Payam
Journal:  ACS Nano       Date:  2020-06-26       Impact factor: 15.881

Review 2.  Advances in microfluidic materials, functions, integration, and applications.

Authors:  Pamela N Nge; Chad I Rogers; Adam T Woolley
Journal:  Chem Rev       Date:  2013-02-14       Impact factor: 60.622

3.  Functionalized Thick Film Impedance Sensors for Use in In Vitro Cell Culture.

Authors:  Heike Bartsch; Martin Baca; Uta Fernekorn; Jens Müller; Andreas Schober; Hartmut Witte
Journal:  Biosensors (Basel)       Date:  2018-04-05
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.