A single center comparison of coiling versus stent assisted coiling in 90 consecutive paraophthalmic region aneurysms.

Geoffrey P Colby1, Alexandra R Paul, Martin G Radvany, Dheeraj Gandhi, Philippe Gailloud, Judy Huang, Rafael J Tamargo, Alexander L Coon.   

Abstract

INTRODUCTION: Aneurysm recurrence is a principle limitation of endovascular coiling procedures, with recurrence rates reported of >30%. The adjunct use of self-expandable stents has revolutionized the treatment of intracranial aneurysms, especially for complex morphologies, wide necks or unfavorable dome to neck ratios. However, further investigation into the durability and outcomes of stent assisted coiling procedures is required.
METHODS: The records of a prospective single center aneurysm database were retrospectively reviewed, and 90 consecutive patients with paraophthalmic aneurysms who underwent coil embolization were identified, 30 of which included stent placement. Patient demographics, aneurysm characteristics, coil packing density, angiographic results (initial and follow-up) and complications were analyzed.
RESULTS: Complete aneurysm occlusion was obtained on initial angiography in 13/30 (43.3%) stented and 19/60 (31.7%) non-stented patients. At ≤24 months (mean follow-up 12.8±6.2 months for stented and 12.8±6.6 months for non-stented group), aneurysm recurrence occurred in 3/26 (11.5%) stented and 14/39 (35.9%) non-stented patients (p<0.05). At the longest follow-up (mean 14.5±12.5 months for stented and 37.6±35.3 months for non-stented), aneurysm recurrence occurred in 4/26 (15.4%) stented and 17/41 (41.5%) non-stented patients (p<0.03). There was no statistically significant correlation between recurrence and aneurysm size or coiling packing.
CONCLUSIONS: Following endovascular coil embolization of paraophthalmic region aneurysms, recurrence rates at 2 years were significantly lower in patients who had stent assisted coiling (11.5%) compared with patients who had coiling procedures without the use of a stent (35.9%). Aneurysm size and coiling packing density did not significantly affect recurrence in our study population.

Entities:  

Mesh:

Year:  2011        PMID: 21990478     DOI: 10.1136/jnis.2011.004911

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  21 in total

1.  Comparison between Solitaire™ AB and Enterprise stent-assisted coiling for intracranial aneurysms.

Authors:  Hua-Wei Ye; Ya-Qi Liu; Qiu-Jing Wang; Tao Zheng; Xu-Bo Cui; Yu-Yuan Gao; Ling-Feng Lai; Xin Zhang; Xi-Feng Li; Shi-Xing Su; Xu-Ying He; Chuan-Zhi Duan
Journal:  Exp Ther Med       Date:  2015-05-08       Impact factor: 2.447

Review 2.  The expanding realm of endovascular neurosurgery: flow diversion for cerebral aneurysm management.

Authors:  Chandan Krishna; Ashish Sonig; Sabareesh K Natarajan; Adnan H Siddiqui
Journal:  Methodist Debakey Cardiovasc J       Date:  2014 Oct-Dec

Review 3.  Complications of endovascular treatment for intracranial aneurysms: Management and prevention.

Authors:  Yon Kwon Ihn; Shang Hun Shin; Seung Kug Baik; In Sup Choi
Journal:  Interv Neuroradiol       Date:  2018-02-21       Impact factor: 1.610

4.  Stent-assisted coiling in endovascular treatment of 500 consecutive cerebral aneurysms with long-term follow-up.

Authors:  S Geyik; K Yavuz; N Yurttutan; I Saatci; H S Cekirge
Journal:  AJNR Am J Neuroradiol       Date:  2013-07-25       Impact factor: 3.825

5.  Endoscopic endonasal transplanum approach to the paraclinoid internal carotid artery.

Authors:  Leon T Lai; Michael K Morgan; Kornkiat Snidvongs; David C W Chin; Ray Sacks; Richard J Harvey
Journal:  J Neurol Surg B Skull Base       Date:  2013-06-20

6.  Effect of hemodynamics on outcome of subtotally occluded paraclinoid aneurysms after stent-assisted coil embolization.

Authors:  Jian Liu; Linkai Jing; Chao Wang; Nikhil Paliwal; Shengzhang Wang; Ying Zhang; Jianping Xiang; Adnan H Siddiqui; Hui Meng; Xinjian Yang
Journal:  J Neurointerv Surg       Date:  2015-11-26       Impact factor: 5.836

7.  Investigating the parameters that affect the radiation exposure and establishing typical values based on procedure complexity for cerebral angiography and brain aneurysm embolization.

Authors:  Chadia Rizk; Ghassan Abi Chedid; Christine Salem; Jad Farah
Journal:  Neuroradiology       Date:  2020-10-14       Impact factor: 2.804

8.  Pipeline Embolization for Salvage Treatment of Previously Stented Residual and Recurrent Cerebral Aneurysms.

Authors:  Matthew T Bender; Chau D Vo; Bowen Jiang; Jessica K Campos; David A Zarrin; Risheng Xu; Erick M Westbroek; Justin M Caplan; Judy Huang; Rafael J Tamargo; Li-Mei Lin; Geoffrey P Colby; Alexander L Coon
Journal:  Interv Neurol       Date:  2018-06-01

9.  Flow diverter-coil technique for endovascular treatment of complex wide neck brain aneurysms, Technical point.

Authors:  Mohammad Ghorbani; Ebrahim Hejazian; Eshagh Bahrami; Abolghasem Mortazavi; Reza Bahrami; Nazila Farnoush
Journal:  Caspian J Intern Med       Date:  2021-04

10.  Use of stent-assisted coil embolization for the treatment of wide-necked aneurysms: A systematic review.

Authors:  Nancy McLaughlin; David L McArthur; Neil A Martin
Journal:  Surg Neurol Int       Date:  2013-03-30
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.