Literature DB >> 21990474

X-configuration intersecting Enterprise stents for vascular remodeling and assisted coil embolization of a wide neck anterior communicating artery aneurysm.

Marc A Lazzaro1, Osama O Zaidat.   

Abstract

BACKGROUND: Intracranial stent technology and techniques have expanded the applications of endovascular therapy for complex intracranial aneurysms. Various methods of stent assisted coil embolization have been described. An additional technique of X-configuration intersecting Enterprise stent implantation with trans-stent microcatheterization for the treatment of a wide neck anterior communicating artery aneurysm is presented.
RESULTS: Successful X-configuration intersecting stent implantation and coil embolization of a wide neck aneurysm is reported with no perioperative complications.
CONCLUSIONS: The technique of trans-stent microcatheterization with X-configuration intersecting Enterprise stent implantation for the treatment of wide neck anterior communicating artery aneurysms is technically feasible. Further study is needed to evaluate technical success, procedural outcome and long term angiographic results.

Entities:  

Mesh:

Year:  2011        PMID: 21990474     DOI: 10.1136/jnis.2011.004796

Source DB:  PubMed          Journal:  J Neurointerv Surg        ISSN: 1759-8478            Impact factor:   5.836


  6 in total

1.  Y-crossing of braided stents with stents and flow diverters does not cause significant stenosis in bench-top studies.

Authors:  Alina Makoyeva; Tim E Darsaut; Igor Salazkin; Jean Raymond
Journal:  Interv Neuroradiol       Date:  2013-12-18       Impact factor: 1.610

2.  Effect of clipping anterior communicating artery aneurysms via pterional approach contralateral to supply of dominant blood: report of 15 patients.

Authors:  Peng Liu; Li Pan; Xuefeng An; Lianting Ma; Ming Yang
Journal:  Int J Clin Exp Med       Date:  2015-02-15

Review 3.  "Coil mainly" policy in management of intracranial ACoA aneurysms: single-centre experience with the systematic review of literature and meta-analysis.

Authors:  Anna Steklacova; Ondrej Bradac; Patricia de Lacy; Jiri Lacman; Frantisek Charvat; Vladimir Benes
Journal:  Neurosurg Rev       Date:  2017-11-28       Impact factor: 3.042

4.  Fatal arterial rupture during angioplasty of a flow diverter in a recurrent, previously Y-stented giant MCA bifurcation aneurysm.

Authors:  Jean-Christophe Gentric; Robert Fahed; Tim E Darsaut; Igor Salazkin; Daniel Roy; Jean Raymond
Journal:  Interv Neuroradiol       Date:  2016-02-17       Impact factor: 1.610

5.  Endovascular treatment with flow diverters may fail to occlude experimental bifurcation aneurysms.

Authors:  Jean Raymond; Tim E Darsaut; Alina Makoyeva; Fabrice Bing; Igor Salazkin
Journal:  Neuroradiology       Date:  2013-08-29       Impact factor: 2.804

Review 6.  Balloons and stents in the endovascular treatment of cerebral aneurysms: vascular anatomy remodeled.

Authors:  Michel Piotin; Raphaël Blanc
Journal:  Front Neurol       Date:  2014-04-08       Impact factor: 4.003

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.