Free-breathing imaging of the heart using 2D cine-GRICS (generalized reconstruction by inversion of coupled systems) with assessment of ventricular volumes and function.

Pierre-André Vuissoz1, Freddy Odille, Brice Fernandez, Maelene Lohezic, Adnane Benhadid, Damien Mandry, Jacques Felblinger.   

Abstract

PURPOSE: To assess cardiac function by means of a novel free-breathing cardiac magnetic resonance imaging (MRI) strategy.
MATERIALS AND METHODS: A stack of ungated 2D steady-state free precession (SSFP) slices was acquired during free breathing and reconstructed as cardiac cine imaging based on the generalized reconstruction by inversion of coupled systems (GRICS). A motion-compensated sliding window approach allows reconstructing cine movies with most motion artifacts cancelled. The proposed reconstruction uses prior knowledge from respiratory belts and electrocardiogram recordings and features a piecewise linear model that relates the electrocardiogram signal to cardiac displacements. The free-breathing protocol was validated in six subjects against a standard breath-held protocol.
RESULTS: Image sharpness, as assessed by the image gradient entropy, was comparable to that of breath-held images and significantly better than in uncorrected images. Volumetric parameters of cardiac function in the left ventricle (LV) and right ventricle (RV) were similar, including end-systolic volumes, end-diastolic volumes and mass, stroke volumes, and ejection fractions (with differences of 3% ± 2.4 in the LV and 2.9% ± 4.4 in the RV). The duration of the free-breathing protocol was nearly the same as the breath-held protocol.
CONCLUSION: Free-breathing cine-GRICS enables accurate assessment of volumetric parameters of cardiac function with efficient correction of motion.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21990103     DOI: 10.1002/jmri.22818

Source DB:  PubMed          Journal:  J Magn Reson Imaging        ISSN: 1053-1807            Impact factor:   4.813


  3 in total

1.  Longitudinal myocardial peak velocities using high temporal resolution phase-contrast and simple averaging are comparable to tissue Doppler echocardiography.

Authors:  Christophe Meyer; Laurent Bonnemains; François Marçon; Pierre-Yves Marie; Jacques Felblinger; Pierre-André Vuissoz
Journal:  MAGMA       Date:  2013-09-08       Impact factor: 2.310

2.  Accelerated motion corrected three-dimensional abdominal MRI using total variation regularized SENSE reconstruction.

Authors:  Gastao Cruz; David Atkinson; Christian Buerger; Tobias Schaeffter; Claudia Prieto
Journal:  Magn Reson Med       Date:  2015-05-21       Impact factor: 4.668

Review 3.  Imaging Techniques for the Study of Fibrosis in Atrial Fibrillation Ablation: From Molecular Mechanisms to Therapeutical Perspectives.

Authors:  Francesco De Sensi; Diego Penela; David Soto-Iglesias; Antonio Berruezo; Ugo Limbruno
Journal:  J Clin Med       Date:  2021-05-24       Impact factor: 4.241

  3 in total