Literature DB >> 2198964

Human immunodeficiency virus DNA amplification and serology in blood donors.

L H Perrin1, S Yerly, N Adami, P Bachmann, E Bütler-Brunner, J Burckhardt, E Kawashima.   

Abstract

The significance of indeterminate screening antibody test for human immunodeficiency virus (HIV) serology is still difficult to evaluate, especially in low-risk populations. One hundred twenty-seven blood donors with an initially reactive screening test for HIV antibodies were enrolled in this study. The sera of 95 of these blood donors were reactive on repetition of the test, and none had detectable circulating p24 antigen. Western blot (WB) analysis of the repeatedly reactive sera was as follows: 9 positive, 31 indeterminate, and 55 negative. One of the blood donors with indeterminate WB later presented a seroconversion. On subsequent control 3 to 12 months later, the sera from donors with indeterminate or negative WB did not present any parameters that may indicate a seroconversion. DNA was purified from citrated blood collected from the 127 blood donors at the time of the initial antibody screening. Five micrograms of each DNA sample corresponding to 7 x 10(5) nucleated white blood cells was amplified by polymerase chain reaction (PCR) in the presence of oligonucleotides (primers) corresponding to a highly conserved segment of the pol gene. The detection of amplified DNA was achieved by dot blot and Southern blot using appropriate 32P-labeled oligonucleotides. Ten DNA samples were positive, 9 corresponded to blood donors with a positive HIV serology, and 1 to the blood donor who later presented a seroconversion. These results confirm the sensitivity of the PCR for the diagnosis of HIV infection; they also suggest that repetition of the serology at 3- to 12-month intervals is a valuable procedure for the control of HIV infection status in blood donors.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2198964

Source DB:  PubMed          Journal:  Blood        ISSN: 0006-4971            Impact factor:   22.113


  4 in total

Review 1.  Frequency, causes, and new challenges of indeterminate results in Western blot confirmatory testing for antibodies to human immunodeficiency virus.

Authors:  Ming Guan
Journal:  Clin Vaccine Immunol       Date:  2007-04-04

2.  Multicenter evaluation of new double-antigen sandwich enzyme immunoassay for measurement of anti-human immunodeficiency virus type 1 and type 2 antibodies.

Authors:  P Burgisser; F Simon; M Wernli; T Wust; M F Beya; P C Frei
Journal:  J Clin Microbiol       Date:  1996-03       Impact factor: 5.948

3.  Characterization of antibodies reacting with HIV gag proteins occasionally found in the serum of non-infected subjects.

Authors:  P Bürgisser; P C Frei
Journal:  Clin Exp Immunol       Date:  1991-08       Impact factor: 4.330

4.  Enzyme-linked oligosorbent assay for detection of polymerase chain reaction-amplified human immunodeficiency virus type 1.

Authors:  F Mallet; C Hebrard; D Brand; E Chapuis; P Cros; P Allibert; J M Besnier; F Barin; B Mandrand
Journal:  J Clin Microbiol       Date:  1993-06       Impact factor: 5.948

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.