Effect of different cleansers on the weight and ion release of removable partial denture: an in vitro study.

Daniela N B Felipucci1, Letícia R Davi, Helena F O Paranhos, Osvaldo L Bezzon, Rodrigo F Silva, Fernando Barbosa Junior, Valéria O Pagnano.   

Abstract

OBJECTIVE: Removable partial dentures (RPD) require different hygiene care, and association of brushing and chemical cleansing is the most recommended to control biofilm formation. However, the effect of cleansers has not been evaluated in RPD metallic components. The aim of this study was to evaluate in vitro the effect of different denture cleansers on the weight and ion release of RPD.
MATERIAL AND METHODS: Five specimens (12x3 mm metallic disc positioned in a 38x18x4 mm mould filled with resin), 7 cleanser agents [Periogard (PE), Cepacol (CE), Corega Tabs (CT), Medical Interporous (MI), Polident (PO), 0.05% sodium hypochlorite (NaOCl), and distilled water (DW) (control)] and 2 cobalt-chromium alloys [DeguDent (DD), and VeraPDI (VPDI)] were used for each experimental situation. One hundred and eighty immersions were performed and the weight was analyzed with a high precision analytic balance. Data were recorded before and after the immersions. The ion release was analyzed using mass spectrometry with inductively coupled plasma. Data were analyzed by two-way ANOVA and Tukey HSD post hoc test at 5% significance level.
RESULTS: Statistical analysis showed that CT and MI had higher values of weight loss with higher change in VPDI alloy compared to DD. The solutions that caused more ion release were NaOCl and MI.
CONCLUSIONS: It may be concluded that 0.05% NaOCl and Medical Interporous tablets are not suitable as auxiliary chemical solutions for RPD care.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21986653      PMCID: PMC3984194          DOI: 10.1590/s1678-77572011000500008

Source DB:  PubMed          Journal:  J Appl Oral Sci        ISSN: 1678-7757            Impact factor:   2.698


INTRODUCTION

Proper cleaning of removable partial dentures (RPD) is important to maintain healthy oral mucosa. Microbial biofilm on the tissues and denture surface is a significant adjuvant in the pathogenesis of denture stomatitis[5,6]. Surface roughness may contribute to the positively correlated rate of microbial colonization, adhesion of microorganisms and biofilm maturation on surfaces[4,8,11,14,16,20]. Webb, et al.[22] (2005) showed that denture biofilm control techniques that use only brushing are not as effective as chemical cleansing in reducing denture biofilm and preventing denture stomatitis associated with Candida. Immersion denture cleansers can be divided into 5 classes: alkaline peroxides, alkaline hypochlorite, diluted acids, disinfecting agents, and enzymes[5,15]. The association of mechanical and chemical methods seems to be the ideal protocol[3,15,17]. RPD frameworks are usually fabricated with cobalt-chromium (Co-Cr) alloys. Because these alloys can corrode or stain as a result of surface contact with the chlorine or oxygen presents in some commercial cleansers, RPD wearers must be instructed about the correct selection of cleansing agents[18,19]. Jagger and Harrison[9] (1995) observed that the patients do not receive correct professional instructions about how to clean their dentures. They overclean the dentures, using homecare products, which could cause harmful effects. One of the required properties for an ideal denture cleanser is not to cause deleterious effects to the material. It is a critical point when considering the use of the products routinely indicated for complete dentures to clean RPD. The alkaline hypochlorite use in resin bases can be harmful to the Co-Cr frameworks. These undesirable effects can be either tarnish (surface discoloration) or corrosion (surface pitting)[2]. In view of the importance of a correct orientation to the patients concerning the more suitable auxiliary methods of cleansing, the aim of this study was to evaluate in vitro the effect of different denture cleansers on the integrity of the Co-Cr alloy used for fabricating RPD. The null hypothesis of this study is that the solutions will have no deleterious effect on the two Co-Cr alloys studied. It is the first time that a low hypochlorite concentration with proven antimicrobial effect in a short period of time[3] is tested for cleaning of RPD metallic components. Webb, et. al.[22] (2002) suggested the use of a smaller concentration (0.02%) with longer immersion time (10 h) for sterilization, but it was not the focus of this study. In spite of this, hypochlorite has some advantages that must be considered such as the low cost, accessibility and effective biofilm removal.

MATERIAL AND METHODS

Two trademarks of alternative Co-Cr alloys were used for this study (Figure 1). Seventy disk-shaped wax patterns (12 mm in diameter x 3 mm thick) were obtained using a Teflon matrix. Thirty-five wax patterns were sprued, invested and cast in each alloy according to manufacturer's instructions. After casting, the specimens were finished with 220-, 400- and 600-grit sandpaper (Norton Abrasives, Saint-Gobain Abrasivos Ltda., Vinhedo, SP, Brazil) in a polishing machine (Model DPU-10, Struers, Ballerup, CO, Denmark) under refrigeration. The cast specimens were then inserted in rectangular places previously prepared with a Teflon rectangular matrix (38 mm x 18 mm x 4 mm) using the conventional dental stone molding technique (Densite, Dentsply Ind. Com. Ltda., Petrópolis, RJ, Brazil). Before packing the heat-cured acrylic resin (Lucitone 550, Dentsply Ind. Com. Ltda), the casting disc was centered in the left side of each rectangular mold and the mold was isolated with a thin layer of separating medium (Cel-Lac, S.S. White Artigos Odontológicos Ltda., Rio de Janeiro, RJ, Brazil). The cure cycle was in water at 73ºC for 90 min and at 94ºC for 30 min. After processing, all specimens were polished in the same machine under refrigeration, followed by polishing cloths and 1-µm diamond suspension (Pasta de Diamante Natural, Fortel Ind. Com, São Paulo, SP, Brazil). All specimens were stored in distilled water at 37±1ºC for 50±2 h, to eliminate the residual monomer.
Figure 1

Alloys

TrademarkManufacturerComposition
DeguDent™Dentsply Ind. e Com. Ltda, Sao Paulo, SP, BrazilCo (64.8%), Cr (28.5%), Mo (5.3%), Si (0.5%), Mn (0.5%), C (0.4%)
Vera PDI®Aalba Dent. Inc., Cordelia, CA, USACo (63.5%), Cr (27%), Mo (5.5%)
Alloys The specimens were dried with absorbent paper and stored in containers away from moisture and heat and were randomly distributed into the 7 groups for each alloy; each group was composed of 5 samples, according to the alloy and cleansing treatment. The specimens were preweighted in an analytical balance accurate to a tenth of a milligram (Model A200DS, Denver Instr. Company, Denver, CO, USA), which was calibrated before each measurement. Subsequently to the initial measurements (T0), the effervescent cleanser solutions were prepared by adding one tablet of each cleanser, Corega Tabs (Corega Tabs, Stafford-Miller Ind., Rio de Janeiro, RJ, Brazil), Medical Interporous (Medical Interporous, MST Laboratories AG, Vaduz, Liechtenstein) or Polident (Polident, GlaxoSmithKline, Philadelphia, PA, USA) to 200 mL of distilled water at 45ºC as recommended by the manufacturer. The groups were stored in an oven (Model DL-AF, DeLeo Equipamentos Laboratoriais, Porto Alegre, RS, Brazil) to keep the temperature. For the storage in the solution, the specimens were positioned in a device developed to this study. The time recommended by the manufacturer was simulated 180 times. For the mouth rinses, Periogard (Colgate-Palmolive Ind. Bras., Osasco, SP, Brazil) or Cepacol (Sanofi-Aventis Farmacêutica Ltda, Suzano, SP, Brazil), sodium hypochlorite (NaOCl) (Q-Boa, Anhembi S/A, Osasco, SP, Brazil) and distilled water group, the immersion time was fixed in 10 min, also performing 180 immersions. All solutions were renewed every 8 h, as suggested by Ünlü, Altay and Sahmali[21] (1996). The containers with the solutions were air-tight and no changes with the environment were done. Furthermore, the manufacturers were consulted and confirmed that the solutions had activity stability in this period of time without changing. After immersion in the respective solutions, each specimen was washed with distilled water for 10 s. After all the immersions, the second weight measurements (T1) were done in the same way as described for the initial analysis. The difference was calculated. Ion release was analyzed using an inductively coupled plasma mass spectrometry - ICP-MS (Model Elan DRC II, Perkin Elmer Sciex, City of Waltham, MA, USA). The containers were disinfected using a hydrochloric acid solution and washed with distilled water. One sample of each solution was collected before the immersion and another sample at the end of the immersions. The solutions were analyzed, and the spectrometer was calibrated to recognize the cobalt and chromium ions. The results of weight loss were subjected to two-way ANOVA and Tukey's post hoc test. All tests were performed with the confidence at an alpha level of 0.05.

RESULTS

The weight changes (g) were recorded as the difference between the weight values in each period of time (T0 and T1). Since the data had a non-normal distribution, ANOVA was performed after logarithmic transformation (normal distributions) of the original data and Tukey post hoc test. There was significant difference among the solutions (p=0.015) and between the alloys (p=0.00). Medical Interporous and Corega Tabs caused the highest values of weight loss (Table 1). The mean values and standard deviations for weight changes of the alloys are presented in Table 2. The Vera PDI showed more weight change than the DeguDent alloy. There was no statistically significant difference when the interactions were evaluated.
Table 1

Means and standard deviation (SD) of weight loss (g) of the alloys after immersion in the solutions

SolutionMean (SD)
Distilled Water0.004 (0.002)a
Sodium Hypochlorite0.005 (0.003)a
Periogard0.005 (0.004)a
Cepacol0.006 (0.004)a
Corega Tabs0.009 (0.006)b
Medical Interporous0.011 (0.003)b
Polident0.005 (0.005)a

Mean values followed by distinct letters are statistically different (p<0.05). The Tukey value is 0.34581

Table 2

Means and standard deviation (SD) of weight loss (g) of the alloys

AlloyMean (SD)
DeguDent0.003 (0.002)a
VeraPDI0.010 (0.006)b

Mean values followed by distinct letters are statistically different (p<0.05)

Means and standard deviation (SD) of weight loss (g) of the alloys after immersion in the solutions Mean values followed by distinct letters are statistically different (p<0.05). The Tukey value is 0.34581 Means and standard deviation (SD) of weight loss (g) of the alloys Mean values followed by distinct letters are statistically different (p<0.05) The values of ion release were obtained using the ICP-MS method. It was recorded the quantity of cobalt and chromium ions in each empty solution. After the immersions, the solutions were collected and submitted to analysis. The results are presented in Table 3.
Table 3

Absolute values of ion release (μg/L)

SolutionsIonsInitialDeguDentVera PDI
Distilled WaterCo0.4123,7885,538
 Cr14,68622,20828,109
Sodium HypochloriteCo0.0135112,3512484,714
 Cr4,9765159,7365747,293
PeriogardCo0.2644,2343,102
 Cr1444,1331481,7061478,518
CepacolCo0.4254,1564,272
 Cr1378,7561442,8021437,308
Corega TabsCo0.16897,024169,355
 Cr251,697303,798454,318
Medical InterporousCo0.1442558,0864124,753
 Cr47,639236,084267,210
PolidentCo4,42987,169195,382
 Cr165,373179,936250,441
Absolute values of ion release (μg/L) It was observed increased release of ions in the solutions after the immersions. Comparing the results, it is possible to note that Vera PDI had a greater quantity of released ions. Among the solutions, NaOCl and Medical Interporous presented the highest values of ion release.

DISCUSSION

The aim of this study was to evaluate the effects of 6 experimental solutions on the cleaning RPD. It was used the dilution of 0.05% NaOCl, which was the lowest concentration found in the literature as adjuvant to hygiene care of complete dentures, with antimicrobial effect[3]. No effect in metallic frameworks has been reported in the literature using this concentration. The literature has shown that 0.5%, 1% or more concentrate solutions can cause harmful effects in metallic components. Sodium perborate-based effervescent tablets (Corega Tabs and Polident) were included in the study in order to compare the methods usually indicated for complete dentures from manufacturers that also indicate the use of these tablets for metallic components without deleterious effects. In the acid category, a citric acid-based tab recently introduced in the market (Medical Interporous) was used, with the manufacturer's indication of use in metallic components with no deleterious effects. Cepacol (0.005% cetylpyridinium chloride) and Periogard (0.12% chlorhexidine gluconate) rinsing solutions were also evaluated for their antimicrobial effects[7,12,13]. Distilled water was used as control. Two Co-Cr alloys with similar compositions were evaluated with the aim of comparing the ion release resistance of the alloys. Weight change of the alloys was evaluated in this study. Keyf and Güngör[10] (2003) found no significant weight change of Co-Cr alloy after immersion in Corega Tabs, Axion and tap water. In the present study, there was significant difference among the solutions. The commercial cleansing tablet affects the reflectance of the surface, but the corrosive effect in Co-Cr alloy was less accentuated than the bleaching effect. In the present study, commercial bleach was not used in the comparison, only different trademarks of cleansing tablets. The Medical Interporous and Corega Tabs caused the highest values of weight loss. Comparing the alloys, it was possible to note that the Vera PDI alloy had lower resistance. These results are in accordance with those of ionic releasing, with a greater release from the Vera PDI alloy. Comparing the solutions, NaOCl and Medical Interporous caused the highest ion release, suggesting corrosion. A total of 180 immersions were simulated, but it is important to consider that the longevity of RPD is at least 5 years. If this ion release continues, undesirable effects might appear, such as brightness loss, porosity, and then biofilm accumulation[4,8,14,16,20]. Although had presented high values of weight loss, the evaluated mouth rinses did not cause any significant deleterious effect to the components in comparison to Medical Interporous and Corega Tabs. It is important to note that the present evaluation did not consider the artificial teeth and some studies have suggested that chlorhexidine may cause tarnishes in these components[1,2]. The objective of this study was to evaluate commercial products to be adjuvant in dentures cleaning and not substitutes to the mechanical method. These solutions must be used combined with brushing and the sum of antimicrobial effect must be considered. It was not the scope of this study to evaluate the antimicrobial effect of any solution, but further studies should evaluate the possibilities of using diluted mouthrinses, if their effectiveness is proven. It will reflect directly in the patients' daily financial investment to denture care.

CONCLUSIONS

It was observed that 0.05% NaOCl is not suitable to be an auxiliary solution in the RPD care because of its corrosion potential. Medical Interporous and 0.05% NaOCl caused a high ion release. Corega Tabs and Medical Interporous caused the highest weight loss after the simulation of 180 immersions.
  22 in total

1.  The effects of surface roughness and type of denture acrylic on biofilm formation by Streptococcus oralis in a constant depth film fermentor.

Authors:  T D Morgan; M Wilson
Journal:  J Appl Microbiol       Date:  2001-07       Impact factor: 3.772

2.  Comparison of effects of bleach and cleansing tablet on reflectance and surface changes of a dental alloy used for removable partial dentures.

Authors:  Filiz Keyf; Tayyar Güngör
Journal:  J Biomater Appl       Date:  2003-07       Impact factor: 2.646

3.  Side effects of immersion-type cleansers on the metal components of dentures.

Authors:  W M Backenstose; J G Wells
Journal:  J Prosthet Dent       Date:  1977-06       Impact factor: 3.426

Review 4.  Denture plaque and denture cleansers: review of the literature.

Authors:  D C Abelson
Journal:  Gerodontics       Date:  1985-10

5.  Materials and methods for cleaning dentures.

Authors:  E Budtz-Jørgensen
Journal:  J Prosthet Dent       Date:  1979-12       Impact factor: 3.426

6.  Evaluation of the sanitization effectiveness of a denture-cleaning product on dentures contaminated with known microbial flora. An in vitro study.

Authors:  R Thomas Glass; James W Bullard; Robert S Conrad; Earl L Blewett
Journal:  Quintessence Int       Date:  2004-03       Impact factor: 1.677

7.  Effect of oral hygiene education and motivation on removable partial denture wearers: longitudinal study.

Authors:  Daniela Garcia Ribeiro; Ana Cláudia Pavarina; Eunice Teresinha Giampaolo; Ana Lucia Machado; Janaina Habib Jorge; Patrícia Petromilli Nordi Sasso Garcia
Journal:  Gerodontology       Date:  2009-06       Impact factor: 2.980

8.  Efficacy of sodium hypochlorite and coconut soap used as disinfecting agents in the reduction of denture stomatitis, Streptococcus mutans and Candida albicans.

Authors:  W Barnabé; T de Mendonça Neto; F C Pimenta; L F Pegoraro; J M Scolaro
Journal:  J Oral Rehabil       Date:  2004-05       Impact factor: 3.837

9.  Effect of denture cleansers on the surface roughness and hardness of a microwave-cured acrylic resin and dental alloys.

Authors:  Renata Cunha Matheus Rodrigues Garcia; de Souza Joane Augusto; Rodrigo Nunes Rached; Altair Antoninha Del Bel Cury
Journal:  J Prosthodont       Date:  2004-09       Impact factor: 2.752

10.  An epidemiologic study of yeasts in elderly denture wearers.

Authors:  E Budtz-Jörgensen; A Stenderup; M Grabowski
Journal:  Community Dent Oral Epidemiol       Date:  1975-05       Impact factor: 3.383

View more
  2 in total

1.  Grapefruit seed extract effectively inhibits the Candida albicans biofilms development on polymethyl methacrylate denture-base resin.

Authors:  Chiaki Tsutsumi-Arai; Kensuke Takakusaki; Yuki Arai; Chika Terada-Ito; Yusuke Takebe; Takahiro Imamura; Shinji Ide; Seiko Tatehara; Reiko Tokuyama-Toda; Noriyuki Wakabayashi; Kazuhito Satomura
Journal:  PLoS One       Date:  2019-05-28       Impact factor: 3.240

2.  Antimicrobial activity of complete denture cleanser solutions based on sodium hypochlorite and Ricinus communis - a randomized clinical study.

Authors:  Marcela Moreira Salles; Maurício Malheiros Badaró; Carolina Noronha Ferraz de Arruda; Vanessa Maria Fagundes Leite; Cláudia Helena Lovato da Silva; Evandro Watanabe; Viviane de Cássia Oliveira; Helena de Freitas Oliveira Paranhos
Journal:  J Appl Oral Sci       Date:  2015 Nov-Dec       Impact factor: 2.698

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.