Literature DB >> 21982962

Screw locking elements: a means to modify the flexibility of osteoporotic fracture fixation with DCPs without compromising system strength or stability.

A Yánez1, A Cuadrado, J A Carta, G Garcés.   

Abstract

This paper analyses whether it is possible to use dynamic compression plates (DCPs) and screw locking elements (SLEs) to vary the flexibility of osteoporotic fracture fixation without compromising the strength and stability of the construct. Compression, torsion and four-point bending static strength tests were conducted. Cyclic load tests of up to 10,000 load cycles were also carried out to determine stiffness performance. Four fixation systems were mounted onto polyurethane bone models. Group 1 consists of the DCP and six cortical screws. Group 2, idem, but with the addition of two SLEs. Group 3, idem, but with the addition of six SLEs. Group 4 used the locking compression plate (LCP) and locking screws. The results indicated no significant difference (p>0.05) in the strength of groups 2-4. It was also observed that the torsional stiffness of group 3 (0.30 Nm/°) was higher than that of group 2 (0.23 Nm/°) and similar to that of group 4 (0.28 Nm/°). Compression stiffness of group 4 (124 N/mm) was higher than that of group 2 (102 N/mm), but lower than that of group 3 (150 N/mm). No notable differences were observed for structural bending stiffness. It is concluded that by using the DCP with SLEs it is possible to modify the stiffness of the fixation construct for the repair of osteoporotic fractures and, in this way, facilitate the conditions suitable on secondary bone healing.
Copyright © 2011 IPEM. Published by Elsevier Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21982962     DOI: 10.1016/j.medengphy.2011.09.015

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  3 in total

1.  Use of screw locking elements improves radiological and biomechanical results of femoral osteotomies.

Authors:  Gerardo L Garcés; Oliver Rodríguez; Enrique Rodríguez Grau-Bassas; Syra Roiz; Alejandro Yánez; Alberto Cuadrado
Journal:  BMC Musculoskelet Disord       Date:  2014-11-21       Impact factor: 2.362

2.  Experimental and numerical investigation into the influence of loading conditions in biomechanical testing of locking plate fracture fixation devices.

Authors:  A MacLeod; A H R W Simpson; P Pankaj
Journal:  Bone Joint Res       Date:  2018-01       Impact factor: 5.853

3.  Bone plate composed of a ternary nano-hydroxyapatite/polyamide 66/glass fiber composite: biomechanical properties and biocompatibility.

Authors:  Bo Qiao; Jidong Li; Qingmao Zhu; Shuquan Guo; Xiaotong Qi; Weichao Li; Jun Wu; Yang Liu; Dianming Jiang
Journal:  Int J Nanomedicine       Date:  2014-03-17
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.