Literature DB >> 2198184

HbA1 in assessment of metabolic control in diabetic BB/E rats.

F J Tames1, J D Baird, A J Bone.   

Abstract

Estimations of HbA1 levels have been used to assess long-term glycaemic control in spontaneously diabetic BB/E rats. The degree of metabolic control achieved by once daily insulin injections and continuous insulin infusion by osmotic minipump was compared. Citrate gel electrophoresis of lysed erythrocytes, previously washed and incubated in 0.9% NaCl, gave accurate HbA1 values without interference from either abnormal Hb variants or labile glycosylation products. Over a 12 week period there was no significant difference in the mean random weekly plasma glucose concentrations between diabetic rats maintained on insulin injections or continuous infusion therapy. The HbA1 values in the injection-treated animals remained unchanged throughout the study period (mean +/- SEM = 5.1 +/- 0.1%). Diabetic rats treated by osmotic minipump showed a steady decline in values over the same period (4.1 +/- 0.1%; p less than 0.001 vs injected rats) but levels remained higher than those recorded in non-diabetic control rats (2.9 +/- 0.01%; p less than 0.001 vs pump-treated rats). These differences in HbA1 were reflected in the plasma glucose values obtained during a 30 h glucose profile performed after six weeks of insulin therapy. Diabetic rats on injection therapy showed considerable diurnal variation in plasma glucose concentration (5.5-11.2 mmol/l; mean 8.9 +/- 0.5) but continuous insulin infusion eliminated the fluctuations giving a significantly lower mean glucose level over the 30 h period (7.3 +/- 0.1 mmol/l; p less than 0.005). HbA1 levels show a poor correlation with random plasma glucose estimations (r = 0.43) but provide a simple and accurate assessment of long-term glycaemic control without the need for multiple 24 h glucose profiles.

Entities:  

Mesh:

Substances:

Year:  1990        PMID: 2198184     DOI: 10.1007/bf00403317

Source DB:  PubMed          Journal:  Diabetologia        ISSN: 0012-186X            Impact factor:   10.122


  19 in total

1.  Further development and automation of a high pressure liquid chromatography method for the determination of glycosylated hemoglobins.

Authors:  P J Dunn; R A Cole; J S Soeldner
Journal:  Metabolism       Date:  1979-07       Impact factor: 8.694

2.  Measurement of glycosylated haemoglobins and glycosylated plasma proteins in animal models with diabetes or inappropriate hypoglycaemia.

Authors:  B J Gould; P R Flatt; S Kotecha; S Collett; S K Swanston-Flatt
Journal:  Horm Metab Res       Date:  1986-12       Impact factor: 2.936

3.  The spontaneously diabetic Wistar rat. Metabolic and morphologic studies.

Authors:  A F Nakhooda; A A Like; C I Chappel; F T Murray; E B Marliss
Journal:  Diabetes       Date:  1977-02       Impact factor: 9.461

4.  Electrophoretically determined haemoglobin A1 concentrations during short-term changes in glucose concentration.

Authors:  R Puukka; M Leppilampi
Journal:  Ann Clin Biochem       Date:  1982-09       Impact factor: 2.057

5.  Glycosylated hemoglobin in human and animal red cells. Role of glucose permeability.

Authors:  P J Higgins; R L Garlick; H F Bunn
Journal:  Diabetes       Date:  1982-09       Impact factor: 9.461

6.  Changes in glycosylated haemoglobin after poor control in insulin-dependent diabetics.

Authors:  A P Brooks; I M Nairn; J D Baird
Journal:  Br Med J       Date:  1980-09-13

7.  Glomerular manifestations of diabetes in the BB rat.

Authors:  D M Brown; M W Steffes; P Thibert; S Azar; S M Mauer
Journal:  Metabolism       Date:  1983-07       Impact factor: 8.694

8.  Haemoglobin A1: An indicator of the metabolic control of diabetic patients.

Authors:  B Gonen; A Rubenstein; H Rochman; S P Tanega; D L Horwitz
Journal:  Lancet       Date:  1977-10-08       Impact factor: 79.321

9.  The determination of glycosylated hemoglobins in rats using high pressure liquid chromatography.

Authors:  M H Blanc; F H Rhie; P J Dunn; J S Soeldner
Journal:  Metabolism       Date:  1981-04       Impact factor: 8.694

10.  Labile glycosylated hemoglobin contributes to hemoglobin A1 as measured by liquid chromatography or electrophoresis.

Authors:  D M Nathan
Journal:  Clin Chem       Date:  1981-07       Impact factor: 8.327

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.