Literature DB >> 21981637

Dose emission and aerodynamic characterization of the terbutaline sulphate dose emitted from a Turbuhaler at low inhalation flow.

M E Abdelrahim1, K H Assi, H Chrystyn.   

Abstract

Previously, dose emission below 30 L min(-1) through DPI has not been routinely determined. However, during routine use some patients do not achieve 30 L min(-1) inhalation flows. Hence, the aim of the present study was to determine dose emission characteristics for low inhalation flows from terbutaline sulphate Turbuhaler. Total emitted dose (TED), fine particle dose (FPD) and mass median aerodynamic diameter (MMAD) of terbutaline sulphate Turbuhaler were determined using inhalation flows of 10-60 L min(-1) and inhaled volume of 4 L. TED and FPD increase significantly with the increase of inhalation flows (p <0.05). Flows had more pronounced effect on FPD than TED, thus, faster inhalation increases respirable amount more than it increases emitted dose. MMAD increases with decrease of inhalation flow until flow of 20L min(-1) then it decreases. In vitro flow dependent dose emission has been demonstrated previously for Turbuhaler for flow rates above 30 L min(-1) but is more pronounced below this flow. Minimal FPD below 30 L min(-1) suggests that during routine use at this flow rate most of emitted dose will impact in mouth. Flow dependent dose emission results suggest that Pharmacopoeias should consider the use variety of inhalation flows rather than one that is equivalent to pressure drop of 4 KPa.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21981637     DOI: 10.3109/10837450.2011.620970

Source DB:  PubMed          Journal:  Pharm Dev Technol        ISSN: 1083-7450            Impact factor:   3.133


  4 in total

Review 1.  Aerosol delivery via noninvasive ventilation: role of models and bioanalysis.

Authors:  Haitham Saeed; Hadeer S Harb; Yasmin M Madney; Mohamed E A Abdelrahim
Journal:  Ann Transl Med       Date:  2021-04

2.  Design and Characterization of Spray-Dried Proliposomes for the Pulmonary Delivery of Curcumin.

Authors:  Islam M Adel; Mohamed F ElMeligy; Mohamed E A Abdelrahim; Amr Maged; AbdelFattah A Abdelkhalek; Azza M M Abdelmoteleb; Nermeen A Elkasabgy
Journal:  Int J Nanomedicine       Date:  2021-04-07

3.  Effect of novel inhaler technique reminder labels on the retention of inhaler technique skills in asthma: a single-blind randomized controlled trial.

Authors:  Iman A Basheti; Nathir M Obeidat; Helen K Reddel
Journal:  NPJ Prim Care Respir Med       Date:  2017-02-09       Impact factor: 2.871

4.  The effect of inspiratory parameters after two separate inhalations on the dose emission of theophylline from low and high resistance dry powder inhalers.

Authors:  Mohamad Abadelah; Jumannah Al-Assadi; James Rooney; Hassane Larhrib
Journal:  Saudi Pharm J       Date:  2019-11-13       Impact factor: 4.330

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.