Application of optical coherence tomography in glaucoma suspect eyes.

Maria Pomorska1, Patrycja Krzyżanowska-Berkowska, Marta Misiuk-Hojło, Hanna Zając-Pytrus, Andrzej Grzybowski.   

Abstract

PURPOSE: The aim of the study was to compare the optical coherence tomography (OCT) parameters of the optic nerve head (ONH) and retinal nerve fibre layer (RNFL) and to identify which measurements are best able to differentiate between normal and glaucoma suspect eyes.
METHODS: The study included 27 eyes with ocular hypertension (OHT), 33 eyes with pre-perimetric glaucoma (PG), 30 perimetrically unaffected eyes of patients with glaucoma in the fellow eye (FE) and 58 eyes of age-matched normal volunteers. All subjects underwent a complete eye examination with standard automated perimetry, optic disc photography and OCT imaging. Peripapillary 'fast RNFL thickness scans' and 'fast optic disc scans' were performed with time-domain OCT. The ONH and RNFL parameters were compared among the four study groups. The ONH and RNFL parameters were examined alone and then combined via four linear discriminant functions (LDF): LDF 1, the optimal combination of ONH parameters; LDF 2, the optimal combination of RNFL parameters; LDF 3, the optimal combination of both ONH and RNFL parameters; and LDF 4, the optimal combination of the best 11 parameters. The areas under the receiver operating curves (AUC) and the sensitivity at fixed specificity of at least 80 and 95 per cent were calculated for single parameters and LDF combinations and then compared. The best 11 parameters were selected based on their AUC values.
RESULTS: Comparative analysis of OCT parameters revealed statistically significant differences in all seven ONH parameters in both PG and FE groups (and only in one ONH measurement in the ocular hypertensive group) when compared with normal eyes. Most of the RNFL parameters demonstrated statistically significant differences in all of the study groups when compared with the control group. The max-min parameter (0.835), inferior quadrant (0.833) and average RNFL thickness (0.829) obtained the highest AUC values in the whole glaucoma suspect group. The rim area had the best diagnostic accuracy among the ONH parameters (AUC = 0.817). The AUC values of the four LDF were: 0.825 (LDF 1), 0.882 (LDF 2), 0.902 (LDF 3) and 0.888 (LDF 4). Statistically significant differences were found between the AUC values of the single best ONH and RNFL parameters and LDF 3 and LDF 4.
CONCLUSIONS: In the present study, RNFL parameters presented with better discriminatory abilities than ONH parameters in the OHT and FE groups. The ONH parameters demonstrated better diagnostic precision in differentiating between PG and normal eyes. The average RNFL thickness, max-min parameter and inferior quadrant RNFL thickness had the best abilities among single OCT measurements for discriminating between glaucoma suspect (including all ocular hypertensive, PG and FE eyes) and normal eyes. The combination of RNFL parameters only or both ONH and RNFL parameters, using linear discriminant analysis, provided the best classification results, improving the diagnostic accuracy of the instrument.
© 2011 The Authors. Clinical and Experimental Optometry © 2011 Optometrists Association Australia.

Entities:  

Mesh:

Year:  2011        PMID: 21981362     DOI: 10.1111/j.1444-0938.2011.00654.x

Source DB:  PubMed          Journal:  Clin Exp Optom        ISSN: 0816-4622            Impact factor:   2.742


  7 in total

1.  Optical coherence tomography use in idiopathic intracranial hypertension.

Authors:  Kiran Malhotra; Tanyatuth Padungkiatsagul; Heather E Moss
Journal:  Ann Eye Sci       Date:  2020-03-15

2.  Association between ganglion cell complex and axial length.

Authors:  Kazunori Hirasawa; Nobuyuki Shoji
Journal:  Jpn J Ophthalmol       Date:  2013-06-08       Impact factor: 2.447

3.  Evaluation of RETICs Glaucoma Diagnostic Calculators in Preperimetric Glaucoma.

Authors:  Javier Moreno-Montañés; Ana García-Nieva; Indira Aristeguieta Osio; Adriano Guarnieri; Antonio Morilla-Grasa; Marta García-Granero; Alfonso Antón
Journal:  Transl Vis Sci Technol       Date:  2018-11-30       Impact factor: 3.283

4.  Choroidal Thickness and its Correlations with Ocular Parameters in Primary Open-angle Glaucoma.

Authors:  Bunyamin Kutluksaman; Guliz Fatma Yavas; Sibel Inan; Mustafa Dogan; Umit Ubeyt Inan
Journal:  Beyoglu Eye J       Date:  2019-12-25

5.  Correlation between retinal nerve fiber layer and disc parameters in glaucoma suspected eyes.

Authors:  Sanja Sefic Kasumovic; Suzana Pavljasevic; Emir Cabric; Milka Mavija; Sabina Dacic-Lepara; Mirko Jankov
Journal:  Med Arch       Date:  2014

Review 6.  Evaluation of Central Macular Thickness and Retinal Nerve Fiber Layer Thickness using Spectral Domain Optical Coherence Tomography in a Tertiary Care Hospital.

Authors:  Prakashchand Agarwal; V K Saini; Saroj Gupta; Anjali Sharma
Journal:  J Curr Glaucoma Pract       Date:  2014-06-12

7.  Optical Coherence Tomography Evaluation of Peripapillary and Macular Structure Changes in Pre-perimetric Glaucoma, Early Perimetric Glaucoma, and Ocular Hypertension: A Systematic Review and Meta-Analysis.

Authors:  Yuxin Tong; Tiantian Wang; Xinyu Zhang; Yi He; Bing Jiang
Journal:  Front Med (Lausanne)       Date:  2021-07-01
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.