Literature DB >> 21978703

Metallosis following knee arthroplasty: a histological and immunohistochemical study.

A Schiavone Panni1, M Vasso, S Cerciello, Giulio Maccauro.   

Abstract

Metallosis represents a rare and severe complication of knee replacement surgery. It is caused by the infiltration and accumulation of metallic debris into the peri-prosthetic structures, deriving from friction between metallic prosthetic components. In knee arthroplasty, this event generally occurs as a result of polyethylene wear of the tibial or metal-back patellar component. The real incidence of metallosis is still unknown, although it seems to be more frequent in hip than in knee arthroplasty. The metallic debris induces a massive release of cytokines from inflammatory cells, making a revision necessary whenever osteolysis and loosening of the prosthesis occur. We report four patients who underwent revision of their knee arthroplasty because of severe metallosis. In one of these patients, polyethylene wear had determined friction between the metal-back patellar component and the anterior portion of the femoral component. In the remaining three cases, metallosis was caused by friction between the femoral and tibial prosthetic metal surfaces, resulting from full-thickness wear of the tibial polyethylene. T lymphocytes were activated by metal particles present in periprosthetic membranes. In all patients, one-stage revision was necessary, with rapid pain disappearance and a complete functional recovery of the knee joint.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21978703     DOI: 10.1177/039463201102400317

Source DB:  PubMed          Journal:  Int J Immunopathol Pharmacol        ISSN: 0394-6320            Impact factor:   3.219


  5 in total

1.  Severe metallosis following total knee arthroplasty: a case report and review of radiographic signs.

Authors:  Camilo Partezani Helito; Carlos Vinícius Buarque de Gusmão; Fabio Janson Angelini; Luis Eduardo Passarelli Tirico; José Ricardo Pécora
Journal:  Skeletal Radiol       Date:  2014-03-25       Impact factor: 2.199

2.  Severe metallosis-related osteolysis as a cause of failure after total knee replacement.

Authors:  Khaled Hamed Salem; Norbert Lindner; Markus Tingart; Alyaa Diaa Elmoghazy
Journal:  J Clin Orthop Trauma       Date:  2019-04-18

3.  Catastrophic metallosis after tumoral knee prosthesis failure: A case report.

Authors:  Luca La Verde; Domenico Fenga; Maria Silvia Spinelli; Francesco Rosario Campo; Michela Florio; Michele Attilio Rosa
Journal:  Int J Surg Case Rep       Date:  2016-11-18

4.  A Unique Case of Extra-articular Extravasation of Metal Into the Lower Leg Resulting From Oxidized Zirconium Wear Particles From Total Knee Arthroplasty.

Authors:  Amanda Purcell; Shelby Buckner; George Brindley; Jerry Grimes
Journal:  Arthroplast Today       Date:  2020-11-20

5.  Pathological analysis of periprosthetic soft tissue and modes of failure in revision total joint arthroplasty patients.

Authors:  Patrick Bettiol; Alec Egan; Cameron Cox; Eric Wait; George Brindley
Journal:  SAGE Open Med       Date:  2021-09-22
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.