Early biomechanical keratoconus pattern measured with an ocular response analyzer: curve analysis.

David Touboul1, Antoine Bénard, Ashraf M Mahmoud, Anne Gallois, Joseph Colin, Cynthia J Roberts.   

Abstract

PURPOSE: To estimate the ability of the Ocular Response Analyzer parameters to aid in the diagnosis of keratoconus in pre-laser in situ keratomileusis (LASIK) patients.
SETTING: Department of Ophthalmology, Bordeaux 2 University, Bordeaux Cedex, France.
DESIGN: Evaluation of diagnostic test.
METHODS: This study compared eyes with mild stages of keratoconus (study group) with preoperative eyes that later had LASIK (control group). Corneas with a central thickness within 500 to 600 μm were targeted. The biomechanical measurements were acquired, and 12 parameters were analyzed after extraction from the signal data.
RESULTS: The study group comprised 103 eyes and the control group, 97 eyes. The mean corneal hysteresis (CH) was 9.2 mm Hg in study eyes and 10.1 mm Hg in control eyes and the mean corneal resistance factor (CRF), 8.9 mm Hg and 10.6 mm Hg, respectively. For a threshold of 9.6, CH had a sensitivity of 66% with a specificity of 67%. For a threshold of 9.7, the CRF had a sensitivity of 72% and a specificity of 77%. For 6 biomechanical parameters, the probability that a patient would present with keratoconus was 3 in 1000 if 1 parameter was over the chosen threshold.
CONCLUSIONS: If 1 of 6 parameters were over a chosen threshold, the probability that a patient would present with keratoconus would be almost 3 in 1000 instead of 9 in 1000 in a LASIK surgery cohort. Despite low sensitivity and specificity, some parameters provided by the corneal analyzer offered high negative likelihood ratios and deserve more study with bigger samples.
Copyright © 2011 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21978610     DOI: 10.1016/j.jcrs.2011.06.029

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  19 in total

1.  Clinical utility of ocular residual astigmatism and topographic disparity vector indexes in subclinical and clinical keratoconus.

Authors:  David P Piñero; Rafael J Pérez-Cambrodí; Roberto Soto-Negro; Pedro Ruiz-Fortes; Alberto Artola
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-09-07       Impact factor: 3.117

2.  [New aspects on biomechanics of the cornea in keratoconus].

Authors:  Z Gatzioufas; B Seitz
Journal:  Ophthalmologe       Date:  2013-09       Impact factor: 1.059

3.  Short-term effects of overnight orthokeratology on corneal epithelial permeability and biomechanical properties.

Authors:  Thao N Yeh; Harry M Green; Yixiu Zhou; Julie Pitts; Britney Kitamata-Wong; Sophia Lee; Shiyin L Wang; Meng C Lin
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-06-06       Impact factor: 4.799

4.  Discriminant value of custom ocular response analyzer waveform derivatives in keratoconus.

Authors:  Katie M Hallahan; Abhijit Sinha Roy; Renato Ambrosio; Marcella Salomao; William J Dupps
Journal:  Ophthalmology       Date:  2013-11-26       Impact factor: 12.079

5.  Custom air puff-derived biomechanical variables in a refractive surgery screening setting: Study from 2 centers.

Authors:  Vinicius S De Stefano; Ibrahim Seven; J Bradley Randleman; William J Dupps
Journal:  J Cataract Refract Surg       Date:  2018-05       Impact factor: 3.351

6.  Multivariate Analysis of the Ocular Response Analyzer's Corneal Deformation Response Curve for Early Keratoconus Detection.

Authors:  Jonatán D Galletti; Pablo R Ruiseñor Vázquez; Fernando Fuentes Bonthoux; Tomás Pförtner; Jeremías G Galletti
Journal:  J Ophthalmol       Date:  2015-05-14       Impact factor: 1.909

7.  Early diagnosis of keratoconus: what difference is it making?

Authors:  Joaquín Fernández Pérez; Almudena Valero Marcos; Francisco Javier Martínez Peña
Journal:  Br J Ophthalmol       Date:  2014-04-23       Impact factor: 4.638

8.  Detection of the early keratoconus based on corneal biomechanical properties in the refractive surgery candidates.

Authors:  Zofia Pniakowska; Piotr Jurowski
Journal:  Indian J Ophthalmol       Date:  2016-02       Impact factor: 1.848

9.  Corneal biomechanics in iatrogenic ectasia and keratoconus: A review of the literature.

Authors:  Majid Moshirfar; Jason N Edmonds; Nicholas L Behunin; Steven M Christiansen
Journal:  Oman J Ophthalmol       Date:  2013-01

Review 10.  Corneal biomechanical properties in different ocular conditions and new measurement techniques.

Authors:  Nery Garcia-Porta; Paulo Fernandes; Antonio Queiros; Jose Salgado-Borges; Manuel Parafita-Mato; Jose Manuel González-Méijome
Journal:  ISRN Ophthalmol       Date:  2014-03-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.