Literature DB >> 21978559

Development of an reliable analytical method for synergistic extractive spectrophotometric determination of cobalt(II) from alloys and nano composite samples by using chromogenic chelating ligand.

Ganesh S Kamble1, Anita A Ghare, Sanjay S Kolekar, Sung H Han, Mansing A Anuse.   

Abstract

A synergistic simple and selective spectrophotometric method was developed for the determination of cobalt(II) with 1-(2',4'-dinitro aminophenyl)-4,4,6-trimethyl-1,4-dihydropyrimidine-2-thiol [2',4'-dinitro APTPT] as a chromogenic reagent. The proposed method has been described on the basis of synergistic effective extraction of cobalt(II) in presence of pyridine at pH range 9.5-10.2, showed orange-red coloured ternary complex having molar ratio 1:2:2 (M:L:Py). The equilibrium time is 10 min for extraction of cobalt(III) from organic phase. The absorbance of coloured organic layer in chloroform is measured spectrophotometrically at 490 nm against reagent blank. The Beer's law was obeyed in the concentration range 2.5-15 μg mL(-1) of cobalt(II) and optimum concentration range was 5-12.5 μg mL(-1) of cobalt(II) and it was evaluated from Ringbom's plot. The molar absorptivity and Sandell's sensitivity of cobalt(II)-2',4'-dinitro APTPT-pyridine complex in chloroform are 1.109×10(3) L mol(-1) cm(-1) and 0.053 μg cm(-2), respectively while molar absorptivity and Sandell's sensitivity of cobalt(II)-2',4'-dinitro APTPT complex in chloroform are 6.22×10(2) L mol(-1) cm(-1) and 0.096 μg cm(-2), respectively. The composition of cobalt(II)-2',4'-dinitro APTPT-pyridine complex (1:2:2) was established by slope ratio method, mole ratio method and Job's method of continuous variation. The ternary complex was stable for more than 48 h. The interfering effects of various cations and anions were also studied, and use of suitable masking agents enhances the selectivity of the method. The method is successfully applied for the determination of cobalt(II) in binary, synthetic mixtures and real samples. A repetition of the method was checked by finding relative standard deviation (R.S.D.) for n=5 which was 0.15%. The reliability of the method is confirmed by comparison of experimental results with atomic absorption spectrophotometer.
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21978559     DOI: 10.1016/j.saa.2011.09.015

Source DB:  PubMed          Journal:  Spectrochim Acta A Mol Biomol Spectrosc        ISSN: 1386-1425            Impact factor:   4.098


  4 in total

1.  Determination of trace metal concentration in compost, DAP, and TSP fertilizers by neutron activation analysis (NAA) and insights from density functional theory calculations.

Authors:  Md Sajjadur Rahman; Syed Mohammod Hossain; Mir Tamzid Rahman; Mohammad A Halim; Mohammad Niaz Ishtiak; Mahbub Kabir
Journal:  Environ Monit Assess       Date:  2017-11-08       Impact factor: 2.513

2.  Radioactive Cobalt(II) Removal from Aqueous Solutions Using a Reusable Nanocomposite: Kinetic, Isotherms, and Mechanistic Study.

Authors:  Xiaotao Zhang; Ximing Wang; Zhangjing Chen
Journal:  Int J Environ Res Public Health       Date:  2017-11-24       Impact factor: 3.390

3.  Spectroscopic Determination of Fluoride Using Eriochrome Black T (EBT) as a Spectrophotometric Reagent from Groundwater.

Authors:  Atinafu G/Mariam; Abebe Diro; Tsegaye Girma Asere; Demelash Jado; Fekadu Melak
Journal:  Int J Anal Chem       Date:  2021-12-28       Impact factor: 1.885

4.  Mean drop behavior in the standard liquid-liquid extraction systems on an L-shaped pulsed sieve-plate column: experiment and modeling.

Authors:  Fatemeh Ardestani; Ahad Ghaemi; Jaber Safdari; Alireza Hemmati
Journal:  RSC Adv       Date:  2022-02-02       Impact factor: 3.361

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.