Literature DB >> 21978532

Bolus electron conformal therapy for the treatment of recurrent inflammatory breast cancer: a case report.

Michelle M Kim1, Rajat J Kudchadker, James E Kanke, Sean Zhang, George H Perkins.   

Abstract

The treatment of locoregionally recurrent breast cancer in patients who have previously undergone radiation therapy is challenging. Special techniques are often required that both eradicate the disease and minimize the risks of retreatment. We report the case of a patient with an early-stage left breast cancer who developed inflammatory-type recurrence requiring re-irradiation of the chest wall using bolus electron conformal therapy with image-guided treatment delivery. The patient was a 51-year-old woman who had undergone lumpectomy, axillary lymph node dissection, and adjuvant whole-breast radiation therapy for a stage I left breast cancer in June 1998. In March 2009, she presented at our institution with biopsy-proven recurrent inflammatory carcinoma and was aggressively treated with multi-agent chemotherapy followed by mastectomy that left a positive surgical margin. Given the patient's prior irradiation and irregular chest wall anatomy, bolus electron conformal therapy was used to treat her chest wall and draining lymphatics while sparing the underlying soft tissue. The patient still had no evidence of disease 21 months after treatment. Our results indicate that bolus electron conformal therapy is an accessible, effective radiation treatment approach for recurrent breast cancer in patients with irregular chest wall anatomy as a result of surgery. This approach may complement standard techniques used to reduce locoregional recurrence in the postmastectomy setting.
Copyright © 2012 American Association of Medical Dosimetrists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21978532     DOI: 10.1016/j.meddos.2011.07.004

Source DB:  PubMed          Journal:  Med Dosim        ISSN: 1873-4022            Impact factor:   1.482


  8 in total

1.  Evaluation of a mixed beam therapy for postmastectomy breast cancer patients: Bolus electron conformal therapy combined with intensity modulated photon radiotherapy and volumetric modulated photon arc therapy.

Authors:  Rui Zhang; David Heins; Mary Sanders; Beibei Guo; Kenneth Hogstrom
Journal:  Med Phys       Date:  2018-05-27       Impact factor: 4.071

2.  Introduction to passive electron intensity modulation.

Authors:  Kenneth R Hogstrom; Robert L Carver; Erin L Chambers; Kevin Erhart
Journal:  J Appl Clin Med Phys       Date:  2017-09-06       Impact factor: 2.102

3.  Potential of 3D printing technologies for fabrication of electron bolus and proton compensators.

Authors:  Wei Zou; Ted Fisher; Miao Zhang; Leonard Kim; Ting Chen; Venkat Narra; Beth Swann; Rachana Singh; Richard Siderit; Lingshu Yin; Boon-Keng Kevin Teo; Michael McKenna; James McDonough; Yue J Ning
Journal:  J Appl Clin Med Phys       Date:  2015-05-08       Impact factor: 2.102

4.  Evaluation of the Eclipse eMC algorithm for bolus electron conformal therapy using a standard verification dataset.

Authors:  Robert L Carver; Conrad P Sprunger; Kenneth R Hogstrom; Richard A Popple; John A Antolak
Journal:  J Appl Clin Med Phys       Date:  2016-05-08       Impact factor: 2.102

5.  Evaluation of Dosimetric Properties of Handmade Bolus for Megavoltage Electron and Photon Radiation Therapy.

Authors:  Endarko Endarko; Siti Aisyah; Chycilia Clara Chandra Carina; Trimawarti Nazara; Gandes Sekartaji; Andreas Nainggolan
Journal:  J Biomed Phys Eng       Date:  2021-12-01

6.  Planning and delivery of intensity modulated bolus electron conformal therapy.

Authors:  Elizabeth N Hilliard; Robert L Carver; Erin L Chambers; James A Kavanaugh; Kevin J Erhart; Andrew S McGuffey; Kenneth R Hogstrom
Journal:  J Appl Clin Med Phys       Date:  2021-09-24       Impact factor: 2.102

7.  Design and production of 3D printed bolus for electron radiation therapy.

Authors:  Shiqin Su; Kathryn Moran; James L Robar
Journal:  J Appl Clin Med Phys       Date:  2014-07-08       Impact factor: 2.102

8.  Useful island block geometries of a passive intensity modulator used for intensity-modulated bolus electron conformal therapy.

Authors:  Erin L Chambers; Robert L Carver; Kenneth R Hogstrom
Journal:  J Appl Clin Med Phys       Date:  2020-11-18       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.