Literature DB >> 21976432

Innovative resource utilization to fashion individualized covered stents in the setting of aortic coarctation.

Damien Kenny1, Qi-Ling Cao, Clifford Kavinsky, Ziyad M Hijazi.   

Abstract

OBJECTIVES: We describe our experience with self-fabricated covered stents in the setting of coarctation of the aorta (CoA).
BACKGROUND: Balloon-expandable covered stents are increasingly being utilized to treat CoA in older children and adults. These stents however, are not available in the United States limiting the interventionalist's ability to treat this condition safely and effectively.
METHODS: Retrospective analysis and follow-up data review of our complete experience with self-fabricated covered stents for CoA. Stents were fashioned by suturing an appropriate length of tubular polytetraflouroethylene to a bare metal stent and deploying this stent across the coarctation in a standardized fashion.
RESULTS: Over a 9-year period we implanted 53 balloon-expandable stents in 49 patients with CoA. Of these 13 were self-fabricated covered stents deployed in 13 patients (7 male). Median age at implantation was 25.4 years (range, 8.7-49.5 years) with median weight of 65.5 kg (range, 28-168 kg). Indications for stent placement were native coarctation/aortic atresia (n = 9), aneurysm formation (n = 3), and re-coarctation (n = 1). The median systolic pressure gradient across the coarctation of 33 mm Hg (range, 12-69 mm Hg) was reduced to 3 mm Hg (range, 0-19 mm Hg) post procedure (P < 0.001). There were no deaths on median follow-up of 44 months (range, 1-83 months). One patient developed acute contained extravasation at implantation, treated with a self-expanding stent graft. Another patient required thrombectomy for femoral arterial thrombosis.
CONCLUSIONS: Innovative application of available materials adds to the armamentarium of the interventionalist. Our self-fabricated covered stent provides effective gradient reduction with no compromise in stent delivery or durability on follow-up.
Copyright © 2011 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21976432     DOI: 10.1002/ccd.22999

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  3 in total

1.  Identifying Gaps in Technology for Congenital Interventions: Analysis of a Needs Survey from Congenital Interventional Cardiologists.

Authors:  Kamel Shibbani; Damien Kenny; Doff McElhinney; Ziyad M Hijazi; Tim Moran
Journal:  Pediatr Cardiol       Date:  2016-04-11       Impact factor: 1.655

Review 2.  Surgical and catheter procedures in adult congenital heart disease: simple national statistics of the UK tell us something.

Authors:  Hideki Uemura
Journal:  Gen Thorac Cardiovasc Surg       Date:  2013-06-05

3.  Miniinvasive interventional bridge to major surgical repair of critical aortic coarctation in a newborn with severe multiorgan failure.

Authors:  Ireneusz Haponiuk; Maciej Chojnicki; Mariusz Steffens; Radosław Jaworski; Aneta Szofer-Sendrowska; Jacek Juscinski; Ewelina Kwasniak; Konrad Paczkowski; Jacek Zielinski; Katarzyna Gierat-Haponiuk
Journal:  Wideochir Inne Tech Maloinwazyjne       Date:  2013-02-28       Impact factor: 1.195

  3 in total