Secil Karakoca-Nemli1, Cemal Aydin, Handan Yilmaz, Bilge Turhan Bal.
Abstract
This article describes a time-saving technique for fabricating a new implant-retained orbital prosthesis using the patient's existing prosthesis. The location of the ocular component is transferred; the position and openings of the palpebral anatomic structures and the precise anatomic details of the existing orbital prosthesis are duplicated. Making the impression, fabricating the definitive cast, alignment of the ocular component, and completing the wax sculpture of the prosthesis are accomplished in one appointment.Entities:
Mesh:
Substances:
Year: 2011 PMID: 21974745 DOI: 10.1111/j.1532-849X.2011.00763.x