Note: anti-strong-disturbance signal processing method of vortex flowmeter with two sensors.

Ke-Jun Xu1, Qing-Lin Luo, Ming Fang, Gang Wang, San-Shan Liu, Yi-Bo Kang, Lei Shi.   

Abstract

Some digital signal processing methods have been used to deal with the output signal of vortex flowmeter for extracting the flow rate frequency from the noisy output of vortex flow rate sensor and achieving the measurement of small flow rate. In applications, however, the power of noise is larger than that of flow rate sometimes. These strong disturbances are caused by pipe vibration mostly. Under this condition the previous digital signal processing methods will be unavailable. Therefore, an anti-strong-disturbance solution is studied for the vortex flowmeter with two sensors in this Note. In this solution, two piezoelectric sensors are installed in the vortex probe. One is called the flow rate sensor for measuring both the flow rate and vibration noise, and the other is called the vibration sensor for detecting the vibration noise and sensing the flow rate signal weakly at the same time. An anti-strong-disturbance signal processing method combining the frequency-domain substation algorithm with the frequency-variance calculation algorithm is proposed to identify the flow rate frequency. When the peak number of amplitude spectrum of the flow rate sensor is different from that of the vibration sensor, the frequency-domain subtraction algorithm will be adopted; when the peak number of amplitude spectrum of the flow rate sensor is the same as that of the vibration sensor, the frequency-variance calculation algorithm will be employed. The whole algorithm is implemented in real time by an ultralow power micro control unit (MCU) to meet requirements of process instrumentation. The experimental results show that this method can obtain the flow rate frequency correctly even if the power of the pipe vibration noise is larger than that of the vortex flow rate signal.
© 2011 American Institute of Physics

Year:  2011        PMID: 21974632     DOI: 10.1063/1.3632119

Source DB:  PubMed          Journal:  Rev Sci Instrum        ISSN: 0034-6748            Impact factor:   1.523


  2 in total

1.  Novel Method for Processing the Dynamic Calibration Signal of Pressure Sensor.

Authors:  Zhongyu Wang; Qiang Li; Zhuoran Wang; Hu Yan
Journal:  Sensors (Basel)       Date:  2015-07-21       Impact factor: 3.576

2.  Vortex Shedding Optical Flowmeter based on Photonic Crystal Fiber.

Authors:  Venugopal Arumuru; Jitendra Narayan Dash; Dhrubaraj Dora; Rajan Jha
Journal:  Sci Rep       Date:  2019-06-05       Impact factor: 4.379

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.