Literature DB >> 21967656

Transthoracic echocardiography guidance during percutaneous closure of patent foramen ovale.

Ali Oto1, Kudret Aytemir, Süheyla Ozkutlu, Ergün Barış Kaya, Hikmet Yorgun, Uğur Canpolat, Ahmet Hakan Ateş, Hilmi Ozkutlu.   

Abstract

BACKGROUND: Percutaneous closure of patent foramen ovale (PFO) has been increasingly performed for several indications; mostly due to cryptogenic stroke. In this study we aimed to evaluate the safety and efficacy of transthoracic echocardiographic (TTE) guidance during percutaneous closure of PFO in using the Amplatzer and Occlutech Figulla PFO occluder devices.
METHODS: Between October 2005 and March 2011, 139 patients (74 male, mean age: 40.4 ± 10.3) underwent transcatheter PFO closure. In all patients transesophageal echocardiography performed subsequently to diagnose, assess the size and evaluate for suitability of the defect for percutaneous closure. During the procedure fluoroscopy and TTE were used for guidance.
RESULTS: Among 139 patients, Amplatzer PFO occluder was used in 74 patients and in 65 of them Occlutech Figulla device was selected for occlusion. The indications for PFO closure were ischemic stroke in 98 (70.5%), recurrent transient ischemic attacks (TIA) in 40 (28.7%), peripheral embolism in 1 (0.8%) of the patients. In all patients, percutaneous intervention was performed successfully under TTE guidance. There have been no neurologic (recurrent strokes or TIAs) and cardiovascular complications during the immediate and long-term follow-up period (2-67 months, median 29). There was significant difference between the mean fluoroscopic time from the beginning which is 8.6 ± 3.4 min in the former versus 3.4 ± 1.9 min in the latter (P < 0.05).
CONCLUSION: Our study confirms the efficacy and safety of TTE guidance during percutaneous closure of PFO, which shortens the procedural time and obviates the need for general anesthesia or endotracheal intubation.
© 2011, Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21967656     DOI: 10.1111/j.1540-8175.2011.01524.x

Source DB:  PubMed          Journal:  Echocardiography        ISSN: 0742-2822            Impact factor:   1.724


  3 in total

1.  Comparison of Figulla Flex® and Amplatzer™ devices for atrial septal defect closure: A meta-analysis.

Authors:  Alvaro Aparisi; Roman J Arnold; Hipólito Gutiérrez; Ana Revilla; Ana Serrador; Benigno Ramos; Tania Rodriguez-Gabella; Alberto Campo; Carlos Baladrón; Itziar Gómez; Manuel Carrasco-Moraleja; José A San Roman; Ignacio J Amat-Santos
Journal:  Cardiol J       Date:  2020-04-24       Impact factor: 2.737

2.  Transcatheter device closure of atrial septal defects guided completely by transthoracic echocardiography: A single cardiac center experience with 152 cases.

Authors:  Qiang Chen; Hua Cao; Gui Can Zhang; Liang Wan Chen; Heng Lu; Lin Li Yu
Journal:  Anatol J Cardiol       Date:  2018-12       Impact factor: 1.596

3.  Percutaneous closure of patent foramen ovale under transthoracic echocardiography guidance-midterm results.

Authors:  Tao Yang; Gianfranco Butera; Wen-Bin Ou-Yang; Guang-Zhi Zhao; Feng-Wen Zhang; Xiang-Bin Pan
Journal:  J Thorac Dis       Date:  2019-06       Impact factor: 2.895

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.