Literature DB >> 21964856

Automated method for the determination of total arsenic and selenium in natural and drinking water by HG-AAS.

Mariela Pistón1, Javier Silva, Ramiro Pérez-Zambra, Isabel Dol, Moisés Knochen.   

Abstract

A multicommutated flow system was designed and evaluated for the determination of total arsenic and selenium by Hydride Generation Atomic Absorption Spectrometry (HG-AAS). It was applied to the determination of arsenic and selenium in samples of natural and drinking water. Detection limits were 0.46 and 0.08 μg l(-1) for arsenic and selenium, respectively; sampling frequency was 120 samples h(-1) for arsenic and 160 samples h(-1) for selenium. Linear ranges found were 1.54-10 μg l(-1) (R = 0.999) for arsenic and 0.27-27 μg l(-1) (R = 0.999) for selenium. Accuracy was evaluated by spiking various water samples and using a reference material. Recoveries were in the range 95-116%. Analytical precision (s ( r ) (%), n = 10) was 6% for both elements. Compared with the Standard Methods, APHA, 3114B manual method, the system consumes at least 10 times less sample per determination, and the quantities of acid and reducing agent used are significantly lower with a reduction in the generation of pollutants and waste. As an additional advantage, the system is very fast, efficient and environmentally friendly for monitoring total arsenic and selenium levels in waters.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21964856     DOI: 10.1007/s10653-011-9436-9

Source DB:  PubMed          Journal:  Environ Geochem Health        ISSN: 0269-4042            Impact factor:   4.609


  7 in total

1.  A multicommuted flow system for the determination of dextrose in parenteral and hemodialysis concentrate solutions.

Authors:  Moisés Knochen; Mariela Pistón; Lourdes Salvarrey; Isabel Dol
Journal:  J Pharm Biomed Anal       Date:  2004-12-25       Impact factor: 3.935

2.  Optimization of a GFAAS method for determination of total inorganic arsenic in drinking water.

Authors:  Jérôme Michon; Véronique Deluchat; Raad Al Shukry; Christophe Dagot; Jean-Claude Bollinger
Journal:  Talanta       Date:  2006-12-13       Impact factor: 6.057

3.  Multicommutated flow system for the determination of glucose in honey with immobilized glucose oxidase reactor and spectrophotometric detection.

Authors:  Alexandra Sixto; Moisés Knochen
Journal:  Talanta       Date:  2008-09-27       Impact factor: 6.057

4.  Analytical methods for inorganic arsenic in water: a review.

Authors:  Dang Q Hung; Olga Nekrassova; Richard G Compton
Journal:  Talanta       Date:  2004-10-08       Impact factor: 6.057

Review 5.  Multi-commutation in flow analysis: recent developments and applications.

Authors:  Mário A Feres; Paula R Fortes; Elias A G Zagatto; João L M Santos; José L F C Lima
Journal:  Anal Chim Acta       Date:  2008-04-24       Impact factor: 6.558

6.  Flow injection-hydride generation atomic absorption spectrometric determination of selenium, arsenic and bismuth.

Authors:  Yanlin Zhang; Samuel B Adeloju
Journal:  Talanta       Date:  2008-04-16       Impact factor: 6.057

7.  Multiparametric flow system for the automated determination of sodium, potassium, calcium, and magnesium in large-volume parenteral solutions and concentrated hemodialysis solutions.

Authors:  Mariela Pistón; Isabel Dol; Moisés Knochen
Journal:  J Autom Methods Manag Chem       Date:  2006
  7 in total
  1 in total

1.  Voltammetric and impedimetric determinations of selenium(iv) by an innovative gold-free poly(1-aminoanthraquinone)/multiwall carbon nanotube-modified carbon paste electrode.

Authors:  Asmaa Galal Ali; Mahmoud Fatehy Altahan; Amr Mohamed Beltagi; Abla Ahmed Hathoot; Magdi Abdel-Azzem
Journal:  RSC Adv       Date:  2022-02-10       Impact factor: 3.361

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.