Literature DB >> 21963479

Simultaneous determination of timolol maleate, rosuvastatin calcium and diclofenac sodium in pharmaceuticals and physiological fluids using HPLC-UV.

Fazli Nasir1, Zafar Iqbal, Abad Khan, Lateef Ahmad, Yasar Shah, Amir Zada Khan, Jamshaid Ali Khan, Salimullah Khan.   

Abstract

A novel HPLC-UV method was developed for the simultaneous determination of timolol (TM), rosuvastatin (RST), and diclofenac sodium (DS) in pharmaceuticals, human plasma and aqueous humor using naproxen sodium as internal standard (IS). The target compounds were analyzed on Hypersil BDS C(18) column (250 mm × 4.6 mm, 5 μm), applying 0.2% triethylamine (TEA) and acetonitrile (ACN) (40:60, v/v), in isocratic mode as mobile phase, pH 2.75 adjusted with 85% phosphoric acid at a flow rate of 1 ml/min. The column oven temperature was kept at 45°C and the peak response was monitored at 284 nm after injecting a 50 μl sample into HPLC system. The direct liquid-liquid extraction procedure was applied to human plasma and bovine aqueous humor samples using mobile phase as an extraction solvent after deproteination with methanol. The different HPLC experimental parameters were optimized and the method was validated according to standard guidelines. The recoveries of the suggested method in human plasma were 98.72, 96.04, and 95.14%, for TM, RST, and DS, while in aqueous humor were 94.99, and 98.23%, for TM, and DS, respectively. The LOD values were found to be 0.800, 0.500, and 0.250 ng/ml, for TM, RST, and DS, respectively, while their respective LOQ values were 2.00, 1.50, and 1.00 ng/ml. The co-efficient of variation (CV) were in the range of 0.1492-1.1729% and 1.0516-4.0104%, for intra-day and inter-day studies, respectively. The method was found accurate in human plasma and bovine aqueous humor and will be applied for the quantification of these compounds in plasma, and aqueous humor samples using animal models and in pharmaceuticals. Copyright Â
© 2011 Elsevier B.V. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21963479     DOI: 10.1016/j.jchromb.2011.09.021

Source DB:  PubMed          Journal:  J Chromatogr B Analyt Technol Biomed Life Sci        ISSN: 1570-0232            Impact factor:   3.205


  4 in total

1.  Sustained Delivery of Timolol Maleate for Over 90 Days by Subconjunctival Injection.

Authors:  Erin Lavik; Markus H Kuehn; Andrew J Shoffstall; Kristyn Atkins; Alina V Dumitrescu; Young H Kwon
Journal:  J Ocul Pharmacol Ther       Date:  2016-11-11       Impact factor: 2.671

2.  Development and Validation of an Ultra Performance Liquid Chromatography Method for the Determination of Dexketoprofen Trometamol, Salicylic Acid and Diclofenac Sodium.

Authors:  Sibel Ilbasmiş Tamer
Journal:  Turk J Pharm Sci       Date:  2017-04-15

3.  Improved bioavailability of timolol maleate via transdermal transfersomal gel: Statistical optimization, characterization, and pharmacokinetic assessment.

Authors:  Nadia M Morsi; Ahmed A Aboelwafa; Marwa H S Dawoud
Journal:  J Adv Res       Date:  2016-07-15       Impact factor: 10.479

4.  Fast separation and quantification of three anti-glaucoma drugs by high-performance liquid chromatography UV detection.

Authors:  Mohamed Walash; Rania El-Shaheny
Journal:  J Food Drug Anal       Date:  2016-01-05       Impact factor: 6.157

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.