Literature DB >> 21962662

Cellulose microfiber functionalized with N,N'-bis (2-aminoethyl)-1,2-ethanediamine as a solid sorbent for the fast preconcentration of Cd(II) in flow system analysis.

Fernanda Midori de Oliveira1, Bruna Fabrin Somera, Marcela Zanetti Corazza, Maria Josefa Santos Yabe, Mariana Gava Segatelli, Emerson Schwingel Ribeiro, Eder Cláudio Lima, Silvio Luís Pereira Dias, César Ricardo Teixeira Tarley.   

Abstract

The present paper describes the synthesis of a new chemically modified cellulose microfiber through oxidation with sodium periodate and functionalization with N,N'-bis (2-aminoethyl)-1,2-ethanediamine for the fast and selective preconcentration of Cd(II) ions in flow system analysis. The new sorbent was characterized by FTIR, SEM, and surface area values. The uptake behavior of Cd(II) ions onto this sorbent was evaluated from kinetic data, pseudo-first-order and pseudo-second-order models, as well as from Langmuir, Freundlich and Langmuir-Freundlich adsorption isotherms. The maximum sorption capacity of 4.59 mg g(-1) was estimated by the Langmuir-Freundlich model with fast kinetics for the sorption of Cd(II) described by the pseudo-second-order kinetic model. After characterization, the sorbent was packed in a mini-column, and a fast flow injection preconcentration system for Cd(II) determination by FAAS was developed. The best Cd(II) preconcentration condition, obtained by means of factorial design and response surface methodology, was achieved at pH 9.36 and a flow rate of 10 mL min(-1) followed by elution with 1.0 mol L(-1) nitric acid. By using 78 s preconcentration time, fast and highly sensitive determination of Cd(II) ions could be achieved with a limit of quantification of 0.20 μg L(-1), preconcentration factor of 26, consumption index of 0.5 mL, concentration efficiency of 20 min(-1), and sample throughput of 39 h(-1). The repeatability for 10 replicate determinations was found to be 7.8 and 2.5% for Cd(II) ion concentrations of 5.0 and 100.0 μg L(-1), respectively. The new sorbent efficiency for the interference-free preconcentration of Cd(II) ions was assessed by analysis of tap, mineral and lake waters, as well as synthetic seawater and normal saline waters. Furthermore, complex samples, such as biological samples, could be analysed by the proposed method in accordance with the accuracy attested by analysis of certified reference materials, TORT-2 (lobster hepatopancreas), and DOLT-4 (dogfish liver).
Copyright © 2011 Elsevier B.V. All rights reserved.

Entities:  

Year:  2011        PMID: 21962662     DOI: 10.1016/j.talanta.2011.07.088

Source DB:  PubMed          Journal:  Talanta        ISSN: 0039-9140            Impact factor:   6.057


  1 in total

1.  Preparation of lactic acid modified cellulose nanoparticles by microwave heating for preconcentration of copper from blood and food samples.

Authors:  Ibrahim Mohamed Kenawy; Wael Ibrahim Mortada; Yasmeen Gaber Abou El-Reash; Aya Atef Mousa
Journal:  Environ Sci Pollut Res Int       Date:  2019-12-27       Impact factor: 4.223

  1 in total