Literature DB >> 21961809

Measurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration.

Qinyi Yan1, Bo Peng, Gang Su, Bruce E Cohan, Terry C Major, Mark E Meyerhoff.   

Abstract

An amperometric needle-type electrochemical glucose sensor intended for tear glucose measurements is described and employed in conjunction with a 0.84 mm i.d. capillary tube to collect microliter volumes of tear fluid. The sensor is based on immobilizing glucose oxidase on a 0.25 mm o.d. platinum/iridium (Pt/Ir) wire and anodically detecting the liberated hydrogen peroxide from the enzymatic reaction. Inner layers of Nafion and an electropolymerized film of 1,3-diaminobenzene/resorcinol greatly enhance the selectivity for glucose over potential interferences in tear fluid, including ascorbic acid and uric acid. Further, the new sensor is optimized to achieve very low detection limits of 1.5 ± 0.4 μM of glucose (S/N = 3) that is required to monitor glucose levels in tear fluid with a glucose sensitivity of 0.032 ± 0.02 nA/μM (n = 6). Only 4-5 μL of tear fluid in the capillary tube is required when the needle sensor is inserted into the capillary. The glucose sensor was employed to measure tear glucose levels in anesthetized rabbits over an 8 h period while also measuring the blood glucose values. A strong correlation between tear and blood glucose levels was found, suggesting that measurement of tear glucose is a potential noninvasive substitute for blood glucose measurements, and the new sensor configuration could aid in conducting further research in this direction.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21961809     DOI: 10.1021/ac201700c

Source DB:  PubMed          Journal:  Anal Chem        ISSN: 0003-2700            Impact factor:   6.986


  20 in total

Review 1.  Wearable biosensors for healthcare monitoring.

Authors:  Jayoung Kim; Alan S Campbell; Berta Esteban-Fernández de Ávila; Joseph Wang
Journal:  Nat Biotechnol       Date:  2019-02-25       Impact factor: 54.908

2.  A graphene-based affinity nanosensor for detection of low-charge and low-molecular-weight molecules.

Authors:  Yibo Zhu; Yufeng Hao; Enoch A Adogla; Jing Yan; Dachao Li; Kexin Xu; Qian Wang; James Hone; Qiao Lin
Journal:  Nanoscale       Date:  2016-03-21       Impact factor: 7.790

Review 3.  Continuous noninvasive glucose monitoring; water as a relevant marker of glucose uptake in vivo.

Authors:  Andreas Caduff; Paul Ben Ishai; Yuri Feldman
Journal:  Biophys Rev       Date:  2019-11-18

4.  Antibody detection in tear samples as a surrogate to monitor host immunity against papillomavirus infections in vaccinated and naturally infected hosts.

Authors:  Jiafen Hu; Sarah Brendle; Karla Balogh; Stephanie Bywaters; Neil Christensen
Journal:  J Gen Virol       Date:  2014-06-05       Impact factor: 3.891

5.  Bioinspired Assemblies and Plasmonic Interfaces for Electrochemical Biosensing.

Authors:  Samuel S Hinman; Quan Cheng
Journal:  J Electroanal Chem (Lausanne)       Date:  2016-05-27       Impact factor: 4.464

Review 6.  Echem methods and electrode types of the current in vivo electrochemical sensing.

Authors:  Qiuye Song; Qianmin Li; Jiadong Yan; Yonggui Song
Journal:  RSC Adv       Date:  2022-06-15       Impact factor: 4.036

Review 7.  Lab-on-a-Contact Lens: Recent Advances and Future Opportunities in Diagnostics and Therapeutics.

Authors:  Yangzhi Zhu; Shaopei Li; Jinghang Li; Natashya Falcone; Qingyu Cui; Shilp Shah; Martin C Hartel; Ning Yu; Patric Young; Natan Roberto de Barros; Zhuohong Wu; Reihaneh Haghniaz; Menekse Ermis; Canran Wang; Heemin Kang; Junmin Lee; Solmaz Karamikamkar; Samad Ahadian; Vadim Jucaud; Mehmet R Dokmeci; Han-Jun Kim; Ali Khademhosseini
Journal:  Adv Mater       Date:  2022-04-11       Impact factor: 32.086

8.  A Disposable Tear Glucose Biosensor-Part 4: Preliminary Animal Model Study Assessing Efficacy, Safety, and Feasibility.

Authors:  Jeffrey T La Belle; Erica Engelschall; Kenneth Lan; Pankti Shah; Neil Saez; Stephanie Maxwell; Teagan Adamson; Michelle Abou-Eid; Kenyon McAferty; Dharmendra R Patel; Curtiss B Cook
Journal:  J Diabetes Sci Technol       Date:  2014-01-01

Review 9.  Trends in Nanomaterial-Based Non-Invasive Diabetes Sensing Technologies.

Authors:  Prashanth Makaram; Dawn Owens; Juan Aceros
Journal:  Diagnostics (Basel)       Date:  2014-04-21

Review 10.  Ultrasensitive detection of proteins and sugars at single-cell level.

Authors:  Satoshi Watabe; Mika Morikawa; Mugiho Kaneda; Kazunari Nakaishi; Akira Nakatsuma; Masaki Ninomiya; Teruki Yoshimura; Toshiaki Miura; Etsuro Ito
Journal:  Commun Integr Biol       Date:  2016-01-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.