Influence of different base thicknesses on maxillary complete denture processing: linear and angular graphic analysis on the movement of artificial teeth.

José Vitor Quinelli Mazaro1, Humberto Gennari Filho, Eduardo Vedovatto, Andressa Paschoal Amoroso, Eduardo Piza Pellizzer, Adriana Cristina Zavanelli.   

Abstract

OBJECTIVE: The purpose of this study was to compare the dental movement that occurs during the processing of maxillary complete dentures with 3 different base thicknesses, using 2 investment methods, and microwave polymerization.
METHODS: A sample of 42 denture models was randomly divided into 6 groups (n = 7), with base thicknesses of 1.25, 2.50, and 3.75 mm and gypsum or silicone flask investment. Points were demarcated on the distal surface of the second molars and on the back of the gypsum cast at the alveolar ridge level to allow linear and angular measurement using AutoCAD software. The data were subjected to analysis of variance with double factor, Tukey test and Fisher (post hoc).
RESULTS: Angular analysis of the varying methods and their interactions generated a statistical difference (P = 0.023) when the magnitudes of molar inclination were compared. Tooth movement was greater for thin-based prostheses, 1.25 mm (-0.234), versus thick 3.75 mm (0.2395), with antagonistic behavior. Prosthesis investment with silicone (0.053) showed greater vertical change compared with the gypsum investment (0.032). There was a difference between the point of analysis, demonstrating that the changes were not symmetric.
CONCLUSIONS: All groups evaluated showed change in the position of artificial teeth after processing. The complete denture with a thin base (1.25 mm) and silicone investment showed the worst results, whereas intermediate thickness (2.50 mm) was demonstrated to be ideal for the denture base.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21959408     DOI: 10.1097/SCS.0b013e31822e5d8c

Source DB:  PubMed          Journal:  J Craniofac Surg        ISSN: 1049-2275            Impact factor:   1.046


  2 in total

1.  Effect of palatal form on movement of teeth during processing of complete denture prosthesis: An in-vitro study.

Authors:  Sumanth Babu; Shaurya Manjunath; Mayuri Vajawat
Journal:  Contemp Clin Dent       Date:  2016 Jan-Mar

2.  Effect of polymerization method and fabrication method on occlusal vertical dimension and occlusal contacts of complete-arch prosthesis.

Authors:  Ana Paula Barbosa Lima; Rafael Pino Vitti; Marina Amaral; Ana Christina Claro Neves; Lais Regiane da Silva Concilio
Journal:  J Adv Prosthodont       Date:  2018-04-18       Impact factor: 1.904

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.