Literature DB >> 21956853

Histopathology of the Ex-PRESS Shunt.

Hassan Aziz1, Francisco Fantes, Sander Dubovy.   

Abstract

The authors report the histopathologic features of a human enucleated eye with an Ex-PRESS shunt (Optonol, Ltd., Neve Ilan, Israel). An 86-year-old man with a blind painful eye underwent enucleation. He had a history of glaucoma with an Ex-PRESS shunt implanted. Histopathologic evaluation of the specimen showed a thin layer of fibrotic tissue surrounding the implant. In this case, the Ex-PRESS shunt was relatively well tolerated in the human eye. Copyright 2011, SLACK Incorporated.

Entities:  

Mesh:

Year:  2011        PMID: 21956853     DOI: 10.3928/15428877-20110922-01

Source DB:  PubMed          Journal:  Ophthalmic Surg Lasers Imaging        ISSN: 1542-8877


  3 in total

1.  Ex-PRESS implantation versus trabeculectomy in uncontrolled glaucoma: a meta-analysis.

Authors:  Wei Wang; Minwen Zhou; Wenbin Huang; Xiulan Zhang
Journal:  PLoS One       Date:  2013-05-31       Impact factor: 3.240

2.  Evaluation of bleb characteristics after implantation of the EX-PRESS™ glaucoma filtration device.

Authors:  Ashley E Laing; Leonard K Seibold; Jeffrey R SooHoo; Malik Y Kahook
Journal:  Mol Vis       Date:  2012-01-04       Impact factor: 2.367

3.  Evaluation of Ex-PRESS implantation combined with phacoemulsification in primary angle-closure glaucoma.

Authors:  Bing Liu; Da-Dong Guo; Xiu-Juan Du; Chen-Yang Cong; Xiao-Hua Ma
Journal:  Medicine (Baltimore)       Date:  2016-09       Impact factor: 1.889

  3 in total