Literature DB >> 21956356

Evaluation of the acute effects of distal coronary microembolization using multidetector computed tomography and magnetic resonance imaging.

Maythem Saeed1, Steven W Hetts, Philip C Ursell, Loi Do, K Pallav Kolli, Mark W Wilson.   

Abstract

The purpose of this study was to test the potential of clinical imaging modalities, 64-slice multidetector computed tomography (MDCT) and 1.5T magnetic resonance imaging (MRI) for qualitative and quantitative evaluation of acute microinfarcts and to determine the effects of <120 μm microemboli on left ventricular function, perfusion, cardiac injury biomarkers, arrhythmia, and cellular and vascular structures. Under X-ray fluoroscopy, 40-120 μm (16 mm(3) ) microemboli were delivered to embolize the left anterior descending (LAD) coronary artery of nine pigs. MDCT/MRI were performed at 72 h in a single session. Microinfarcts were visible in six of nine animals on delayed contrast-enhanced MDCT/MR images but measurable in all animals using semiautomated threshold methods. Other MDCT and MRI sequences demonstrated decline in left ventricular ejection fraction, regional strain and perfusion in visible and invisible microinfarcted regions. Microemboli caused significant elevation in cardiac injury enzymes and arrhythmias. Various sizes of microinfarcts appeared microscopically as distinct aggregates of macrophages replacing myocardium. Semiautomated threshold methods are necessary to measure and confirm/deny the presence of myocardial microinfarcts. This study offers support for alternative applications of MDCT/MRI in assessing clinical cases in which microemboli <120 μm escape protective devices during percutaneous coronary interventions. Although microembolization resulted in no mortality, it caused left ventricular dysfunction, perfusion deficit, cellular damage increase in cardiac injury enzymes, and arrhythmias.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21956356     DOI: 10.1002/mrm.23149

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  6 in total

1.  Value of MR contrast media in image-guided body interventions.

Authors:  Maythem Saeed; Mark Wilson
Journal:  World J Radiol       Date:  2012-01-28

Review 2.  Magnetic resonance imaging and multi-detector computed tomography assessment of extracellular compartment in ischemic and non-ischemic myocardial pathologies.

Authors:  Maythem Saeed; Steven W Hetts; Robert Jablonowski; Mark W Wilson
Journal:  World J Cardiol       Date:  2014-11-26

3.  MRI quantification of left ventricular function in microinfarct versus large infarct in swine model.

Authors:  Maythem Saeed; Steve W Hetts; Loi Do; Sammir M Sullivan; Mark W Wilson
Journal:  Int J Cardiovasc Imaging       Date:  2012-10-13       Impact factor: 2.357

4.  Assessment of microembolization associated with revascularization in acute myocardial infarction: MDCT cardiac perfusion and function study.

Authors:  Maythem Saeed; Steven W Hetts; Loi Do; Mark W Wilson
Journal:  Int J Cardiovasc Imaging       Date:  2013-09-26       Impact factor: 2.357

5.  Magnetic resonance imaging characterization of circumferential and longitudinal strain under various coronary interventions in swine.

Authors:  Mohammed Sa Suhail; Mark W Wilson; Steven W Hetts; Maythem Saeed
Journal:  World J Radiol       Date:  2013-12-28

Review 6.  A fresh look at coronary microembolization.

Authors:  Petra Kleinbongard; Gerd Heusch
Journal:  Nat Rev Cardiol       Date:  2021-11-16       Impact factor: 49.421

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.