Fracture of a titanium sleeve-encased third-generation ceramic liner in a modern THA.

Pranit N Chotai1, Edwin P Su.   

Abstract

Due to their excellent tribology, ceramics are increasingly used for total hip arthroplasty (THA) in young patients. Fracture rates for contemporary ceramics range from 0% to 0.004%. Recently, ceramic liners are encased in a titanium sleeve to further decrease the chances of fracture. We encountered 1 case of a metal-encased acetabular liner fracture in a ceramic-on-ceramic articulation in a series of 764 hips. Our literature review revealed no reports of metal-encased ceramic liner fracture. A 60-year-old woman presented 27 months after a bilateral ceramic-on-ceramic THA. She reported mechanical grinding and clicking from the left hip on extension. There was no history of trauma or fall. Examination revealed a nonantalgic gait and audible-palpable crepitations on the left hip. Range of motion of the left hip was intact with no subluxation. Radiographs revealed fractured ceramic insert and an excessively anteverted socket on the left side. Intraoperative findings revealed gross impingement in the form of indentation of the metal femoral neck against the elevated metal rim encasing the liner. Revision THA was performed using an uncemented polyethylene liner while retaining the well-fixed cup and stem. The Harris Hip Score at 4.5-year follow-up was 100, with no evidence of osteolysis or polyethylene wear. Copyright 2011, SLACK Incorporated.

Entities:  

Mesh:

Year:  2011        PMID: 21956067     DOI: 10.3928/01477447-20110826-30

Source DB:  PubMed          Journal:  Orthopedics        ISSN: 0147-7447            Impact factor:   1.390


  7 in total

1.  Suboptimal Component Position Leading to Severe Wear of an Alumina-Alumina Total Hip Coupling: Biomechanical Analysis and Documentation of Limited Tissue Response.

Authors:  Jaime A Carvajal Alba; Marcella E Elpers; Andrew E Rosenberg; Raymond P Robinson
Journal:  HSS J       Date:  2015-05-27

2.  Ceramic liner fracture and impingement in total hip arthroplasty.

Authors:  Amy Steinhoff; Victor Hakim; Richard H Walker; Clifford W Colwell; Steven N Copp
Journal:  HSS J       Date:  2014-10-21

3.  Design Considerations for the Next Generation Hip Resurfacing Implant: Commentary.

Authors:  Edwin P Su
Journal:  HSS J       Date:  2016-12-19

Review 4.  Ceramic-Ceramic Bearing: Too Unpredictable to Use it Regularly.

Authors:  Edwin P Su
Journal:  HSS J       Date:  2012-09-05

Review 5.  Fracture of ceramic bearing surfaces following total hip replacement: a systematic review.

Authors:  Francesco Traina; Marcello De Fine; Alberto Di Martino; Cesare Faldini
Journal:  Biomed Res Int       Date:  2013-06-13       Impact factor: 3.411

6.  Could larger diameter of 4th generation ceramic bearing increase the rate of squeaking after THA?: A retrospective study.

Authors:  Yuan Luo; Xue-Feng Sun; Jin Chen; Wei Cui; Tao Wang
Journal:  Medicine (Baltimore)       Date:  2018-12       Impact factor: 1.817

7.  Long-Term Results of Delta Ceramic-on-Ceramic Total Hip Arthroplasty.

Authors:  Thomas J Blumenfeld; Joel Politi; Sean Coker; Tammy O'Dell; William Hamilton
Journal:  Arthroplast Today       Date:  2022-01-18
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.