Literature DB >> 21955328

Laser flow measurements in an idealized total cavopulmonary connection with mechanical circulatory assistance.

Steven G Chopski1, Emily Downs, Christopher M Haggerty, Ajit P Yoganathan, Amy L Throckmorton.   

Abstract

This study examined the interactive fluid dynamics between a cavopulmonary assist device and univentricular Fontan circulation. We conducted two-dimensional particle image velocimetry measurements on an idealized total cavopulmonary connection (TCPC) with an axial pump prototype intravascularly inserted into the inferior vena cava (IVC) and then in the IVC and the superior vena cava (SVC) for a dual-pump support case. The glass model of the TCPC consisted of rigid vessels having a diameter of 13.4 mm and a one-diameter vessel offset at the TCPC junction. Fluid velocity profiles were examined at a cardiac output of 3 L/min and SVC and IVC flow ratios of 30/70%, 40/60%, and 50/50% and pump rotational speeds from 3000 to 9000 rpm. In addition, cardiac outputs of 5 and 7 L/min were also examined. As compared to the flow profile with the pump present, the measured velocity field demonstrated the presence of rotational (i.e., out of plane) motion, which forced the higher-velocity regions toward the periphery of the vessel. As a result, few flow vortices were captured in the image plane downstream of the pump in the TCPC junction. However, the velocity profiles for all cases demonstrated the expected shunting preference of IVC flow toward the right pulmonary artery. Furthermore, the inclusion of the pump provided a pressure rise of 3 to 9 mm Hg, which would be sufficient to relieve systemic hypertension in Fontan patients with circulatory dysfunction.
© 2011, Copyright the Authors. Artificial Organs © 2011, International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

Entities:  

Mesh:

Year:  2011        PMID: 21955328     DOI: 10.1111/j.1525-1594.2011.01345.x

Source DB:  PubMed          Journal:  Artif Organs        ISSN: 0160-564X            Impact factor:   3.094


  4 in total

Review 1.  Recent advances in computational methodology for simulation of mechanical circulatory assist devices.

Authors:  Alison L Marsden; Yuri Bazilevs; Christopher C Long; Marek Behr
Journal:  Wiley Interdiscip Rev Syst Biol Med       Date:  2014-01-21

2.  A practical and less invasive total cavopulmonary connection sheep model.

Authors:  Dongfang Wang; Mark Plunkett; Guodong Gao; Xiaoqin Zhou; Cherry Ballard-Croft; Hassan Reda; Joseph B Zwischenberger
Journal:  ASAIO J       Date:  2014 Mar-Apr       Impact factor: 2.872

3.  A viable therapeutic option: mechanical circulatory support of the failing Fontan physiology.

Authors:  Amy L Throckmorton; Sergio Lopez-Isaza; Emily A Downs; Steven G Chopski; James J Gangemi; William Moskowitz
Journal:  Pediatr Cardiol       Date:  2013-02-15       Impact factor: 1.655

4.  A paired membrane umbrella double-lumen cannula ensures consistent cavopulmonary assistance in a Fontan sheep model.

Authors:  Dongfang Wang; Guodong Gao; Mark Plunkett; Guangfeng Zhao; Stephen Topaz; Cherry Ballard-Croft; Joseph B Zwischenberger
Journal:  J Thorac Cardiovasc Surg       Date:  2014-05-16       Impact factor: 5.209

  4 in total