Literature DB >> 21953680

Long-term follow-up of polytetrafluoroethylene-covered stents implanted during percutaneous coronary intervention for management of acute coronary perforation.

Kevin A Copeland1, James T Hopkins, William S Weintraub, Ehsanur Rahman.   

Abstract

OBJECTIVE: To determine the long-term outcomes for patients receiving polytetrafluoroethylene (PTFE)-covered stents as definitive therapy, in our institution, for the management of acute coronary perforation.
BACKGROUND: Coronary perforation as a complication of percutaneous coronary intervention (PCI) is associated with high morbidity and mortality. Management options included observation only or a combination of several or all of these approaches: reversal of anticoagulation, prolonged balloon inflation, deployment of a standard stent, emergent cardiac surgery, or insertion of a PTFE-covered stent.
METHODS: With our IRB approval, records of 12,093 consecutive patients who received PCI during a 5-year period from January 2002 to December 2006 were reviewed and 50 patients who had coronary perforation as a complication of PCI were identified.
RESULTS: Of the 21 patients who received a PTFE-covered stent to manage coronary perforation, one died secondary to acute thrombosis within the PTFE-covered stent in the first 24 hrs and one required emergent cardiac surgery due to continued contrast extravasation despite PTFE-covered stent deployment. The other 19 patients were followed long term (mean 55 months) and only one survivor had a potentially life-threatening outcome (subacute stent thrombosis) over that time period.
CONCLUSION: Utilization of a PTFE-covered stent may be a reasonable short- and long-term option to manage acute coronary perforation that occurs during PCI. On the basis of this limited experience, successful PTFE-covered stent deployment as the conclusive treatment for coronary perforation is associated with a favorable long-term event-free survival rate.
Copyright © 2011 Wiley Periodicals, Inc.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21953680     DOI: 10.1002/ccd.23339

Source DB:  PubMed          Journal:  Catheter Cardiovasc Interv        ISSN: 1522-1946            Impact factor:   2.692


  3 in total

1.  Successful management of Ellis type III left anterior descending artery perforation following percutaneous coronary intervention by a covered stent: Successfully resolved the dramatic complication.

Authors:  Sunil Kumar Srinivas; Soumya Patra; Rangaraj Ramalingam; Navin Agrawal; Tanveer Syed; Ravindranath K Shankarappa; Cholenahalli Nanjappa Manjunath
Journal:  J Cardiovasc Dis Res       Date:  2014-02-18

2.  Efficacy and Biosafety of a New Bioresorbable Vascular Scaffold Covered with Biodegradable Film in Rabbits: An In Vivo Study.

Authors:  Wei Cai; En Chen; Xiaoling Zeng; Canqiang Chen; Lingzhen Wu; Xingchun Zheng; Lianglong Chen
Journal:  Acta Cardiol Sin       Date:  2020-11       Impact factor: 2.672

3.  Histologic analysis of a covered stent implanted for pseudoaneurysm in a coronary artery.

Authors:  Evan A Alston; Brigitta C Brott; Vijay K Misra; Constantine L Athanasuleas; Peter G Anderson; Silvio H Litovsky
Journal:  Cardiovasc Pathol       Date:  2013-03-07       Impact factor: 2.185

  3 in total