Literature DB >> 21953098

Liquid microjunction surface sampling probe fluid dynamics: computational and experimental analysis of coaxial intercapillary positioning effects on sample manipulation.

Mariam S Elnaggar1, Charlotte Barbier, Gary J Van Berkel.   

Abstract

A coaxial geometry liquid microjunction surface sampling probe (LMJ-SSP) enables direct extraction of analytes from surfaces for subsequent analysis by techniques like mass spectrometry. Solution dynamics at the probe-to-sample surface interface in the LMJ-SSP has been suspected to influence sampling efficiency and dispersion but has not been rigorously investigated. The effect on flow dynamics and analyte transport to the mass spectrometer caused by coaxial retraction of the inner and outer capillaries from each other and the surface during sampling with a LMJ-SSP was investigated using computational fluid dynamics and experimentation. A transparent LMJ-SSP was constructed to provide the means for visual observation of the dynamics of the surface sampling process. Visual observation, computational fluid dynamics (CFD) analysis, and experimental results revealed that inner capillary axial retraction from the flush position relative to the outer capillary transitioned the probe from a continuous sampling and injection mode through an intermediate regime to sample plug formation mode caused by eddy currents at the sampling end of the probe. The potential for analytical implementation of these newly discovered probe operational modes is discussed.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21953098     DOI: 10.1007/s13361-011-0145-5

Source DB:  PubMed          Journal:  J Am Soc Mass Spectrom        ISSN: 1044-0305            Impact factor:   3.109


  16 in total

1.  Electrospray device for coupling microscale separations and other miniaturized devices with electrospray mass spectrometry.

Authors:  T Wachs; J Henion
Journal:  Anal Chem       Date:  2001-02-01       Impact factor: 6.986

2.  An improved thin-layer chromatography/mass spectrometry coupling using a surface sampling probe electrospray ion trap system.

Authors:  Michael J Ford; Gary J Van Berkel
Journal:  Rapid Commun Mass Spectrom       Date:  2004       Impact factor: 2.419

3.  Molecular characterization of organic aerosols using nanospray-desorption/electrospray ionization-mass spectrometry.

Authors:  Patrick J Roach; Julia Laskin; Alexander Laskin
Journal:  Anal Chem       Date:  2010-10-01       Impact factor: 6.986

4.  Thin-layer chromatography/electrospray ionization triple-quadrupole linear ion trap mass spectrometry system: analysis of rhodamine dyes separated on reversed-phase C8 plates.

Authors:  Michael J Ford; Vilmos Kertesz; Gary J Van Berkel
Journal:  J Mass Spectrom       Date:  2005-07       Impact factor: 1.982

5.  Liquid microjunction surface sampling probe electrospray mass spectrometry for detection of drugs and metabolites in thin tissue sections.

Authors:  Gary J Van Berkel; Vilmos Kertesz; Kenneth A Koeplinger; Marissa Vavrek; Ah-Ng Tony Kong
Journal:  J Mass Spectrom       Date:  2008-04       Impact factor: 1.982

6.  Evaluation of a surface-sampling probe electrospray mass spectrometry system for the analysis of surface-deposited and affinity-captured proteins.

Authors:  Gary J Van Berkel; Michael J Ford; Mitchel J Doktycz; Stephen J Kennel
Journal:  Rapid Commun Mass Spectrom       Date:  2006       Impact factor: 2.419

7.  Established and emerging atmospheric pressure surface sampling/ionization techniques for mass spectrometry.

Authors:  Gary J Van Berkel; Sofie P Pasilis; Olga Ovchinnikova
Journal:  J Mass Spectrom       Date:  2008-09       Impact factor: 1.982

8.  High-throughput mode liquid microjunction surface sampling probe.

Authors:  Gary J Van Berkel; Vilmos Kertesz; Richard C King
Journal:  Anal Chem       Date:  2009-08-15       Impact factor: 6.986

9.  A device for automated direct sampling and quantitation from solid-phase sorbent extraction cards by electrospray tandem mass spectrometry.

Authors:  Timothy Wachs; Jack Henion
Journal:  Anal Chem       Date:  2003-04-01       Impact factor: 6.986

10.  Self-aspirating atmospheric pressure chemical ionization source for direct sampling of analytes on surfaces and in liquid solutions.

Authors:  Keiji G Asano; Michael J Ford; Bruce A Tomkins; Gary J Van Berkel
Journal:  Rapid Commun Mass Spectrom       Date:  2005       Impact factor: 2.419

View more
  8 in total

1.  Liquid microjunction surface sampling probe fluid dynamics: characterization and application of an analyte plug formation operational mode.

Authors:  Mariam S ElNaggar; Gary J Van Berkel
Journal:  J Am Soc Mass Spectrom       Date:  2011-08-10       Impact factor: 3.109

2.  Real-time metabolomics on living microorganisms using ambient electrospray ionization flow-probe.

Authors:  Cheng-Chih Hsu; Mariam S ElNaggar; Yao Peng; Jinshu Fang; Laura M Sanchez; Samantha J Mascuch; Kirsten A Møller; Emad K Alazzeh; Jiri Pikula; Robert A Quinn; Yi Zeng; Benjamin E Wolfe; Rachel J Dutton; Lena Gerwick; Lixin Zhang; Xueting Liu; Maria Månsson; Pieter C Dorrestein
Journal:  Anal Chem       Date:  2013-07-11       Impact factor: 6.986

3.  Use of an Open Port Sampling Interface Coupled to Electrospray Ionization for the On-Line Analysis of Organic Aerosol Particles.

Authors:  Kenneth D Swanson; Anne L Worth; Gary L Glish
Journal:  J Am Soc Mass Spectrom       Date:  2017-09-11       Impact factor: 3.109

Review 4.  Ambient Mass Spectrometry Imaging Using Direct Liquid Extraction Techniques.

Authors:  Julia Laskin; Ingela Lanekoff
Journal:  Anal Chem       Date:  2015-11-24       Impact factor: 6.986

5.  Spatially-Resolved Top-down Proteomics Bridged to MALDI MS Imaging Reveals the Molecular Physiome of Brain Regions.

Authors:  Vivian Delcourt; Julien Franck; Jusal Quanico; Jean-Pascal Gimeno; Maxence Wisztorski; Antonella Raffo-Romero; Firas Kobeissy; Xavier Roucou; Michel Salzet; Isabelle Fournier
Journal:  Mol Cell Proteomics       Date:  2017-11-09       Impact factor: 5.911

6.  MALDI MS Guided Liquid Microjunction Extraction for Capillary Electrophoresis-Electrospray Ionization MS Analysis of Single Pancreatic Islet Cells.

Authors:  Troy J Comi; Monika A Makurath; Marina C Philip; Stanislav S Rubakhin; Jonathan V Sweedler
Journal:  Anal Chem       Date:  2017-07-06       Impact factor: 6.986

7.  Electro-focusing liquid extractive surface analysis (EF-LESA) coupled to mass spectrometry.

Authors:  A Gareth Brenton; A Ruth Godfrey
Journal:  Anal Chem       Date:  2014-03-20       Impact factor: 6.986

8.  Ambient ionisation mass spectrometry for in situ analysis of intact proteins.

Authors:  Klaudia I Kocurek; Rian L Griffiths; Helen J Cooper
Journal:  J Mass Spectrom       Date:  2018-07       Impact factor: 1.982

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.