Literature DB >> 21950896

Comparative study of viscoelastic arterial wall models in nonlinear one-dimensional finite element simulations of blood flow.

Rashmi Raghu1, Irene E Vignon-Clementel, C Alberto Figueroa, Charles A Taylor.   

Abstract

It is well known that blood vessels exhibit viscoelastic properties, which are modeled in the literature with different mathematical forms and experimental bases. The wide range of existing viscoelastic wall models may produce significantly different blood flow, pressure, and vessel deformation solutions in cardiovascular simulations. In this paper, we present a novel comparative study of two different viscoelastic wall models in nonlinear one-dimensional (1D) simulations of blood flow. The viscoelastic models are from papers by Holenstein et al. in 1980 (model V1) and Valdez-Jasso et al. in 2009 (model V2). The static elastic or zero-frequency responses of both models are chosen to be identical. The nonlinear 1D blood flow equations incorporating wall viscoelasticity are solved using a space-time finite element method and the implementation is verified with the Method of Manufactured Solutions. Simulation results using models V1, V2 and the common static elastic model are compared in three application examples: (i) wave propagation study in an idealized vessel with reflection-free outflow boundary condition; (ii) carotid artery model with nonperiodic boundary conditions; and (iii) subject-specific abdominal aorta model under rest and simulated lower limb exercise conditions. In the wave propagation study the damping and wave speed were largest for model V2 and lowest for the elastic model. In the carotid and abdominal aorta studies the most significant differences between wall models were observed in the hysteresis (pressure-area) loops, which were larger for V2 than V1, indicating that V2 is a more dissipative model. The cross-sectional area oscillations over the cardiac cycle were smaller for the viscoelastic models compared to the elastic model. In the abdominal aorta study, differences between constitutive models were more pronounced under exercise conditions than at rest. Inlet pressure pulse for model V1 was larger than the pulse for V2 and the elastic model in the exercise case. In this paper, we have successfully implemented and verified two viscoelastic wall models in a nonlinear 1D finite element blood flow solver and analyzed differences between these models in various idealized and physiological simulations, including exercise. The computational model of blood flow presented here can be utilized in further studies of the cardiovascular system incorporating viscoelastic wall properties.

Mesh:

Year:  2011        PMID: 21950896     DOI: 10.1115/1.4004532

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  3 in total

1.  Uncertainty Quantification in a Patient-Specific One-Dimensional Arterial Network Model: EnKF-Based Inflow Estimator.

Authors:  Andrea Arnold; Christina Battista; Daniel Bia; Yanina Zócalo German; Ricardo L Armentano; Hien Tran; Mette S Olufsen
Journal:  J Verif Valid Uncertain Quantif       Date:  2017-02-22

Review 2.  Proinflammatory Arterial Stiffness Syndrome: A Signature of Large Arterial Aging.

Authors:  Mingyi Wang; Robert E Monticone; Kimberly R McGraw
Journal:  J Vasc Res       Date:  2018-08-02       Impact factor: 1.934

3.  On the accuracy of displacement-based wave intensity analysis: Effect of vessel wall viscoelasticity and nonlinearity.

Authors:  Jingyi Kang; Arian Aghilinejad; Niema M Pahlevan
Journal:  PLoS One       Date:  2019-11-01       Impact factor: 3.240

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.