Literature DB >> 21950894

In silico prediction of the mechanobiological response of arterial tissue: application to angioplasty and stenting.

Colin J Boyle1, Alexander B Lennon, Patrick J Prendergast.   

Abstract

One way to restore physiological blood flow to occluded arteries involves the deformation of plaque using an intravascular balloon and preventing elastic recoil using a stent. Angioplasty and stent implantation cause unphysiological loading of the arterial tissue, which may lead to tissue in-growth and reblockage; termed "restenosis." In this paper, a computational methodology for predicting the time-course of restenosis is presented. Stress-induced damage, computed using a remaining life approach, stimulates inflammation (production of matrix degrading factors and growth stimuli). This, in turn, induces a change in smooth muscle cell phenotype from contractile (as exists in the quiescent tissue) to synthetic (as exists in the growing tissue). In this paper, smooth muscle cell activity (migration, proliferation, and differentiation) is simulated in a lattice using a stochastic approach to model individual cell activity. The inflammation equations are examined under simplified loading cases. The mechanobiological parameters of the model were estimated by calibrating the model response to the results of a balloon angioplasty study in humans. The simulation method was then used to simulate restenosis in a two dimensional model of a stented artery. Cell activity predictions were similar to those observed during neointimal hyperplasia, culminating in the growth of restenosis. Similar to experiment, the amount of neointima produced increased with the degree of expansion of the stent, and this relationship was found to be highly dependant on the prescribed inflammatory response. It was found that the duration of inflammation affected the amount of restenosis produced, and that this effect was most pronounced with large stent expansions. In conclusion, the paper shows that the arterial tissue response to mechanical stimulation can be predicted using a stochastic cell modeling approach, and that the simulation captures features of restenosis development observed with real stents. The modeling approach is proposed for application in three dimensional models of cardiovascular stenting procedures.

Entities:  

Mesh:

Year:  2011        PMID: 21950894     DOI: 10.1115/1.4004492

Source DB:  PubMed          Journal:  J Biomech Eng        ISSN: 0148-0731            Impact factor:   2.097


  11 in total

1.  Mathematical modelling of the restenosis process after stent implantation.

Authors:  Javier Escuer; Miguel A Martínez; Sean McGinty; Estefanía Peña
Journal:  J R Soc Interface       Date:  2019-08-14       Impact factor: 4.118

2.  Mathematical modeling of collagen turnover in biological tissue.

Authors:  Pablo Sáez; Estefanía Peña; Miguel Ángel Martínez; Ellen Kuhl
Journal:  J Math Biol       Date:  2012-11-06       Impact factor: 2.259

3.  Feasibility study for removing calcified material using a planar rectangular ultrasound transducer.

Authors:  Christakis Damianou; Andreas Couppis
Journal:  J Ultrasound       Date:  2016-01-12

4.  A predictive multiscale model of in-stent restenosis in femoral arteries: linking haemodynamics and gene expression with an agent-based model of cellular dynamics.

Authors:  Anna Corti; Monika Colombo; Jared M Rozowsky; Stefano Casarin; Yong He; Dario Carbonaro; Francesco Migliavacca; Jose F Rodriguez Matas; Scott A Berceli; Claudio Chiastra
Journal:  J R Soc Interface       Date:  2022-03-30       Impact factor: 4.118

5.  Investigating atherosclerotic plaque phantoms for ultrasound therapy.

Authors:  Michalis Sotiriou; Marinos Yiannakou; Christakis Damianou
Journal:  J Ultrasound       Date:  2022-01-31

6.  A dynamical system that describes vein graft adaptation and failure.

Authors:  Marc Garbey; Scott A Berceli
Journal:  J Theor Biol       Date:  2013-07-16       Impact factor: 2.691

7.  A computational bio-chemo-mechanical model of in vivo tissue-engineered vascular graft development.

Authors:  Ramak Khosravi; Abhay B Ramachandra; Jason M Szafron; Daniele E Schiavazzi; Christopher K Breuer; Jay D Humphrey
Journal:  Integr Biol (Camb)       Date:  2020-04-14       Impact factor: 2.192

8.  A homogenized constrained mixture model of restenosis and vascular remodelling after balloon angioplasty.

Authors:  Lauranne Maes; An-Sofie Cloet; Inge Fourneau; Nele Famaey
Journal:  J R Soc Interface       Date:  2021-05-05       Impact factor: 4.118

9.  A Comparison of Fully-Coupled 3D In-Stent Restenosis Simulations to In-vivo Data.

Authors:  Pavel S Zun; Tatiana Anikina; Andrew Svitenkov; Alfons G Hoekstra
Journal:  Front Physiol       Date:  2017-05-23       Impact factor: 4.566

10.  Removing atherosclerotic plaque created using high cholesterol diet in rabbit using ultrasound.

Authors:  Christakis Damianou; Christos Christofi; Nicos Mylonas
Journal:  J Ther Ultrasound       Date:  2015-01-29