Literature DB >> 21946545

Intraocular pressure: Goldmann tonometry, computational model, and calibration equation.

Andrés Fernando Guzmán1, Alejandro Arciniegas Castilla, Fabio Ariel Guarnieri, Fernando Ramírez Rodríguez.   

Abstract

PURPOSE: There exists a concern about the general accuracy of intraocular pressure (IOP) measurements using tonometry, and especially Goldmann applanation tonometer (GAT) because it considers the cornea as an infinite thin shell. In this study, the relationship between the true IOP and tonometric IOP, external curvature radius (ECR), and central corneal thickness (CCT) is explored.
METHODS: In this study, the calibration of the IOP measurements through GAT for different values of CCT, ECR, and E (Young modulus), is done through computational simulations of the mechanical behavior of the cornea subjected to the applanation process using the finite element method (FEM). Previous to this simulations, experimentations on rabbits were performed to confirm that inaccurate readings are obtained with GAT in certain conditions. This methodology is also followed to establish the range of corneal parameters of patients for which the GAT measure of pressure is reliable. The calibration equation for GAT measurements is developed from a statistical multiple linear regression analysis.
RESULTS: Based on a statistical variable analysis of the computational modeling results, a calibration equation is established for the GAT that relates the true IOP with the ECR, CCT, and GAT measurements.
CONCLUSIONS: Our results show that GAT measures are linearly dependent on the modulus of elasticity of the cornea; nevertheless, if we consider a healthy cornea with a specific modulus of elasticity, it is possible to correct the measure with a linear equation involving CCT and ECR.

Entities:  

Mesh:

Year:  2013        PMID: 21946545     DOI: 10.1097/IJG.0b013e31822f4747

Source DB:  PubMed          Journal:  J Glaucoma        ISSN: 1057-0829            Impact factor:   2.503


  2 in total

1.  Citius, Altius, Fortius: Agreement between Perkins and Dynamic Contour Tonometry (Pascal) and the Impact of Altitude.

Authors:  Oscar Albis-Donado; Shibal Bhartiya; Marina Gil-Reyes; Giovanna Casale-Vargas; Nancy Arreguin-Rebollar; Malik Y Kahook
Journal:  J Curr Glaucoma Pract       Date:  2018-03-01

2.  Effect of SCUBA Diving on Ophthalmic Parameters.

Authors:  Laurent Deleu; Janet Catherine; Laurence Postelmans; Costantino Balestra
Journal:  Medicina (Kaunas)       Date:  2022-03-09       Impact factor: 2.430