Hyperecho in ultrasound images during high-intensity focused ultrasound ablation for hepatocellular carcinomas.

Hiroyuki Fukuda1, Kazushi Numata, Akito Nozaki, Masaaki Kondo, Manabu Morimoto, Katsuaki Tanaka, Ryu Ito, Masao Ohto, Yoshiharu Ishibashi, Noriyoshi Oshima, Ayao Ito, Hui Zhu, Zhi-Biao Wang.   

Abstract

High-intensity focused ultrasound (HIFU) is a noninvasive method that can cause complete coagulation necrosis without requiring the insertion of any instruments. The hyperechoic grayscale change (hyperechoic region) is used as a sign that the treated lesion has been completely coagulated. The purpose of this study was to evaluate the first hyperechoic region during treatment using HIFU ablation according to various conditions, such as the sonication power, the depth of the tumor from the surface of the skin, and the shield rate. HIFU treatment was performed in 20 patients. The HIFU system (Chongqing Haifu Tech, Chongqing, China) was used under ultrasound guidance. Complete coagulation was achieved in 17 cases. Hyperechoic region were detected after HIFU ablation in 17 patients. The size of the hyperechoic region at a depth of >50 mm was significantly smaller than that at a depth of ≤50 mm. The number and power of the sonications for areas at a depth of >50 mm were significantly larger than those for areas at a depth of ≤50 mm. The number and power in cases with a shield rate of 31-60% were significantly larger than those in cases with a shield rate of 0-30%. When the shield rate was 0%, a hyperechoic region occurred, even when a maximum sonication power was not used. In all three cases with tumors located at a depth of greater than 70 mm and a shield rate of larger than 60%, a hyperechoic region was not seen. In conclusion, hyperechoic regions are easy to visualize in cases with tumors located at a depth of ≤50 mm or shield rates of 0-30%.
Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

Entities:  

Mesh:

Year:  2011        PMID: 21945355     DOI: 10.1016/j.ejrad.2011.09.001

Source DB:  PubMed          Journal:  Eur J Radiol        ISSN: 0720-048X            Impact factor:   3.528


  3 in total

1.  Advances in ultrasound systems for hepatic lesions in Japan.

Authors:  Kazushi Numata
Journal:  J Med Ultrason (2001)       Date:  2015-07       Impact factor: 1.314

Review 2.  Magnetic resonance image-guided versus ultrasound-guided high-intensity focused ultrasound in the treatment of breast cancer.

Authors:  Sheng Li; Pei-Hong Wu
Journal:  Chin J Cancer       Date:  2012-12-14

3.  In Vitro and In Vivo Investigation of High-Intensity Focused Ultrasound (HIFU) Hat-Type Ablation Mode.

Authors:  Hongya Dai; Fei Chen; Sijing Yan; Xiaoya Ding; Dazhao Ma; Jing Wen; Die Xu; Jianzhong Zou
Journal:  Med Sci Monit       Date:  2017-07-12
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.