Literature DB >> 21943120

Cumulative postural exposure measured by a novel device: a preliminary study.

Daniel Cury Ribeiro1, Gisela Sole, J Haxby Abbott, Stephan Milosavljevic.   

Abstract

The aim of the present study was to examine the within-day reliability of the Spineangel® postural monitoring device and to measure cumulative lumbo-pelvic posture exposure of health care workers. Twenty-one workers from an aged-care residential home wore the Spineangel, attached to the belt or waistband of their normal work apparel, during a period of the work shift. To assess the within-day reliability of measurements, 11 workers performed two sets of three lumbo-pelvic forward flexion, sustaining them for five 5 s each, at the beginning and at the end of the work shift. Different thresholds for cumulative postural exposure were measured. The reliability was found to be excellent (ICC = 0.81). On average, a threshold of 30° of lumbo-pelvic forward flexion was exceeded 1069 times/h (SD 2157.1); at 45°, 121 times/h (SD 223.8); and at 60°, 8 times/h (SD 21.8). The use of Spineangel is thus likely to be a useful device for monitoring work posture. STATEMENT OF RELEVANCE: The Spineangel® is capable of providing reliable postural measurements in the workplace. Different cumulative postural exposure thresholds were established considering three domains of cumulative exposure: magnitude (range of motion), frequency and duration. The implementation of such domains for cumulative exposure allowed us to explore interesting forms of monitoring posture exposure.

Mesh:

Year:  2011        PMID: 21943120     DOI: 10.1080/00140139.2011.600776

Source DB:  PubMed          Journal:  Ergonomics        ISSN: 0014-0139            Impact factor:   2.778


  5 in total

1.  Effectiveness of a lumbopelvic monitor and feedback device to change postural behaviour: a protocol for the ELF cluster randomised controlled trial.

Authors:  Daniel Cury Ribeiro; Stephan Milosavljevic; J Haxby Abbott
Journal:  BMJ Open       Date:  2017-01-10       Impact factor: 2.692

2.  Evaluation of a Training Program to Reduce Stressful Trunk Postures in the Nursing Professions: A Pilot Study.

Authors:  Agnessa Kozak; Sonja Freitag; Albert Nienhaus
Journal:  Ann Work Expo Health       Date:  2017-01-01       Impact factor: 2.179

Review 3.  Comparing lumbo-pelvic kinematics in people with and without back pain: a systematic review and meta-analysis.

Authors:  Robert A Laird; Jayce Gilbert; Peter Kent; Jennifer L Keating
Journal:  BMC Musculoskelet Disord       Date:  2014-07-10       Impact factor: 2.362

4.  How consistent are lordosis, range of movement and lumbo-pelvic rhythm in people with and without back pain?

Authors:  Robert A Laird; Peter Kent; Jennifer L Keating
Journal:  BMC Musculoskelet Disord       Date:  2016-09-22       Impact factor: 2.362

Review 5.  Understanding Monitoring Technologies for Adults With Pain: Systematic Literature Review.

Authors:  Iyubanit Rodríguez; Valeria Herskovic; Carmen Gerea; Carolina Fuentes; Pedro O Rossel; Maíra Marques; Mauricio Campos
Journal:  J Med Internet Res       Date:  2017-10-27       Impact factor: 5.428

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.