Literature DB >> 21942236

Data comparison between two dental spectrophotometers.

G Khashayar1, A Dozic, C J Kleverlaan, A J Feilzer.   

Abstract

OBJECTIVES: The objective of this study was to clinically test whether the data from two different spectrophotometers, based on spot and surface measurements, can be compared.
METHODS: Under standardized clinical conditions two devices (Vita Easyshade and Spectro Shade-Micro) were used to record the color of three areas (cervical, middle, and incisal) per tooth for three upper maxillary anterior teeth in 102 participants. Each position was measured three times to attain an average for the CIE L*a*b* coordinates and to attain the corresponding Vita Classical shade tab integrated in the software of both devices. Vita tabs were also described as L*a*b* values using earlier published translations so that color differences (ΔE) could be calculated between them.
RESULTS: The regression analysis between the two devices showed that the independent correlation coefficients of the L*a*b* values are low. Yet when the suggested shade codes are compared with Vita colors instead of L*a*b*, 40% of the cases were equal and 51% were clinically acceptable. SIGNIFICANCE: According to this study the two devices do not give a comparable shade selection output, and thus the exchange of L*a*b* values between the two spectrophotometers cannot be recommended.

Entities:  

Mesh:

Year:  2011        PMID: 21942236     DOI: 10.2341/11-161-C

Source DB:  PubMed          Journal:  Oper Dent        ISSN: 0361-7734            Impact factor:   2.440


  5 in total

1.  Color-Matching and Blending-Effect of Universal Shade Bulk-Fill-Resin-Composite in Resin-Composite-Models and Natural Teeth.

Authors:  Rasha M Abdelraouf; Nour A Habib
Journal:  Biomed Res Int       Date:  2016-10-23       Impact factor: 3.411

2.  Spectrophotometric Evaluation of Polyetheretherketone (PEEK) as a Core Material and a Comparison with Gold Standard Core Materials.

Authors:  Bogna Stawarczyk; Philipp Schmid; Malgorzata Roos; Marlis Eichberger; Patrick R Schmidlin
Journal:  Materials (Basel)       Date:  2016-06-20       Impact factor: 3.623

3.  Porcelain color alteration after orthodontic bonding using three different surface preparation methods.

Authors:  Mehrnaz Moradinezhad; Mina Moradi; Milad Shamohammadi; Elham Hormozi; Amir Ghorani
Journal:  Dent Res J (Isfahan)       Date:  2018 May-Jun

4.  Influence of core color on final shade reproduction of zirconia crown in single central incisor situation - An in vivo study.

Authors:  Ghada M Ayash; Essam Ossman; Lucette G Segaan; Mohammad Rayyan; Christelle Joukhadar
Journal:  J Clin Exp Dent       Date:  2020-01-01

Review 5.  Tooth shade analysis and selection in prosthodontics: A systematic review and meta-analysis.

Authors:  Siddhesh Borse; Sachin Haribhau Chaware
Journal:  J Indian Prosthodont Soc       Date:  2020-04-07
  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.