Literature DB >> 21938314

Single cycle to failure in bending of three standard and five locking plates and plate constructs.

C A Blake1, R J Boudrieau, B S Torrance, E K Tacvorian, J B Cabassu, G R Gaudette, M P Kowaleski.   

Abstract

OBJECTIVE: To evaluate the biomechanical properties of standard and locking plates in bending. We hypothesised that titanium (Ti) constructs would have the greatest deformation and that String of Pearl (SOP) constructs would have the greatest strength and stiffness, and would behave differently compared to plates alone.
METHODS: Dynamic compression plates (DCP), stainless steel (SS) limited contact (LC)-DCP®, Ti LC-DCP, locking compression plates (LCP), 10 mm and 11 mm advanced locking plate system (ALPS 10 / 11), SOP and Fixin plates were evaluated individually and as constructs applied to a validated bone model simulating a bridging osteosynthesis. Bending stiffness and strength were compared using one-way ANOVA with post hoc Tukey, and unpaired t-test (p <0.05).
RESULTS: The SOP plates had significantly greater stiffness than all other plates; Ti LC-DCP, ALPS 10 and Fixin plates had significantly lower stiffness than all other plates. The SOP constructs had the highest mean bending stiffness, and strength that was significantly different from only the Ti LC-DCP, ALPS 10 and Fixin constructs. The ALPS 10 constructs had the lowest mean bending stiffness, and strength that was significantly different from only ALPS 11 and SOP constructs. Comparison of bending structural stiffness of plates versus constructs showed a significant difference in all plate pairs except for the DCP and ALPS 10. CLINICAL RELEVANCE: Due to differing plate construct properties inherent to these diverse implant systems, identical approaches to fracture management and plate application cannot be applied.

Entities:  

Mesh:

Year:  2011        PMID: 21938314     DOI: 10.3415/VCOT-11-04-0061

Source DB:  PubMed          Journal:  Vet Comp Orthop Traumatol        ISSN: 0932-0814            Impact factor:   1.358


  2 in total

1.  A biomechanical comparison of conventional dynamic compression plates and string-of-pearls™ locking plates using cantilever bending in a canine Ilial fracture model.

Authors:  Allison R Kenzig; James R Butler; Lauren B Priddy; Kristen R Lacy; Steven H Elder
Journal:  BMC Vet Res       Date:  2017-07-13       Impact factor: 2.741

2.  Retrospective evaluation of perioperative and short term clinical outcomes in appendicular long bone skeleton fractures repaired via the string of pearls (SOP) locking plate system.

Authors:  Matthew R Field; Ryan Butler; Robert W Wills; Wilburn M Maxwell
Journal:  BMC Vet Res       Date:  2018-12-05       Impact factor: 2.741

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.