Literature DB >> 21937891

Validity of the StepWatch Step Activity Monitor: preliminary findings for use in persons with Parkinson disease and multiple sclerosis.

Amy L Schmidt1, Melissa L Pennypacker, Aaron H Thrush, Carol I Leiper, Rebecca L Craik.   

Abstract

BACKGROUND: One goal for older adults with Parkinson disease (PD) and multiple sclerosis (MS) is community ambulation; however, the best way for clinicians to measure this has not been established. Self-report questionnaires rely on the participant's cognitive function and reporting accuracy, while the association between clinical timed walk tests and community ambulation may not be strong. Progress toward the identification of an appropriate clinical tool to measure strides in PD and MS populations is hampered by the lack of meaningful research and reference standards in this area.
PURPOSE: The objective of the present study was to explore the validity of the StepWatch Step Activity Monitor (SAM) in assessing stride count in persons with PD or MS. The SAM is a 2-dimensional accelerometer that counts strides and is calibrated for individual participants.
METHODS: A convenience sample of 20 participants completed a health history interview. Participants ambulated approximately 15 m while wearing the SAM to establish appropriate baseline calibrations, matching their stride with the device settings. Next, participants took 3 passes over the GaitMat II (GM II) while wearing the SAM. Strides counted by the GM were compared with the strides counted by the SAM.
RESULTS: The Pearson correlation coefficients (r) for MS and PD, respectively, were 0.99 and 1.0.
CONCLUSIONS: Our investigation presents preliminary data that shows the concurrent validity of the SAM when compared with the gold standard GM. The SAM appears to be a valid tool for use in persons with PD and MS. The validity was apparent in a population of widely varying impairment levels.

Entities:  

Mesh:

Year:  2011        PMID: 21937891     DOI: 10.1519/JPT.0b013e31820aa921

Source DB:  PubMed          Journal:  J Geriatr Phys Ther        ISSN: 1539-8412            Impact factor:   3.381


  15 in total

1.  Filtering for productive activity changes outcomes in step-based monitoring among children.

Authors:  Michael Wininger; Kristie Bjornson
Journal:  Physiol Meas       Date:  2016-11-24       Impact factor: 2.833

2.  A Randomized Crossover Trial of Dalfampridine Extended Release for Effect on Ambulatory Activity in People with Multiple Sclerosis.

Authors:  Theodore R Brown; Virginia I Simnad
Journal:  Int J MS Care       Date:  2016 Jul-Aug

3.  Step detection using multi- versus single tri-axial accelerometer-based systems.

Authors:  E Fortune; V A Lugade; S Amin; K R Kaufman
Journal:  Physiol Meas       Date:  2015-11-23       Impact factor: 2.833

4.  Barriers to exercise in people with Parkinson disease.

Authors:  Terry Ellis; Jennifer K Boudreau; Tamara R DeAngelis; Lisa E Brown; James T Cavanaugh; Gammon M Earhart; Matthew P Ford; K Bo Foreman; Leland E Dibble
Journal:  Phys Ther       Date:  2013-01-03

Review 5.  How Wearable Sensors Can Support Parkinson's Disease Diagnosis and Treatment: A Systematic Review.

Authors:  Erika Rovini; Carlo Maremmani; Filippo Cavallo
Journal:  Front Neurosci       Date:  2017-10-06       Impact factor: 4.677

Review 6.  A brief review of recent Charcot-Marie-Tooth research and priorities.

Authors:  Sean Ekins; Nadia K Litterman; Renée J G Arnold; Robert W Burgess; Joel S Freundlich; Steven J Gray; Joseph J Higgins; Brett Langley; Dianna E Willis; Lucia Notterpek; David Pleasure; Michael W Sereda; Allison Moore
Journal:  F1000Res       Date:  2015-02-26

7.  Accuracy of StepWatch™ and ActiGraph accelerometers for measuring steps taken among persons with multiple sclerosis.

Authors:  Brian M Sandroff; Robert W Motl; Lara A Pilutti; Yvonne C Learmonth; Ipek Ensari; Deirdre Dlugonski; Rachel E Klaren; Swathi Balantrapu; Barry J Riskin
Journal:  PLoS One       Date:  2014-04-08       Impact factor: 3.240

Review 8.  Physical Activity Monitoring in Patients with Neurological Disorders: A Review of Novel Body-Worn Devices.

Authors:  Oonagh M Giggins; Ieuan Clay; Lorcan Walsh
Journal:  Digit Biomark       Date:  2017-06-12

9.  Day-to-Day Variability of Walking Performance Measures in Individuals Poststroke and Individuals With Parkinson Disease.

Authors:  Carey L Holleran; Marghuretta D Bland; Darcy S Reisman; Terry D Ellis; Gammon M Earhart; Catherine E Lang
Journal:  J Neurol Phys Ther       Date:  2020-10       Impact factor: 4.655

10.  Free-living and laboratory gait characteristics in patients with multiple sclerosis.

Authors:  Fabio A Storm; K P S Nair; Alison J Clarke; Jill M Van der Meulen; Claudia Mazzà
Journal:  PLoS One       Date:  2018-05-01       Impact factor: 3.240

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.