Literature DB >> 21933471

Reference values for echocardiographic measurements of healthy newborns.

Alper Güzeltaş1, Ayşe Güler Eroğlu.   

Abstract

OBJECTIVE: To assess the reference values of M-mode echocardiographic measurements in healthy newborns according to body weight.
METHODS: From January, 2008 to June, 2008, a total of 250 - 130 female and 120 male - term healthy newborns were included in the study. M-mode echocardiographic measurements were recorded by a paediatric cardiologist in accordance with the American Society of Echocardiography recommendations. Right ventricular anterior wall end-diastolic thickness, right ventricular end-diastolic diameter, interventricular septum end-diastolic thickness, left ventricular end-diastolic diameter, left ventricular posterior wall end-diastolic thickness, interventricular septum end-systolic thickness, left ventricular end-systolic diameter, left ventricular posterior wall end-systolic thickness, aortic root dimension, left atrium dimension, left ventricular ejection, and shortening fraction were measured.
RESULTS: The values of echocardiographic measurements revealed a good correlation with body weight. When body weight increased, the measured values also increased in parallel. The measured values were not influenced by gender. Ejection and shortening fraction parameters did not change with body weight and gender.
CONCLUSION: In this study, normative values related to body weight for cardiac chambers and wall thickness were determined in healthy newborns. These reference values can be used to evaluate whether newborns have normal or abnormal echocardiographic measurement.

Mesh:

Year:  2011        PMID: 21933471     DOI: 10.1017/S1047951111001259

Source DB:  PubMed          Journal:  Cardiol Young        ISSN: 1047-9511            Impact factor:   1.093


  5 in total

1.  Comprehensive echocardiographic assessment of biventricular function in the rabbit, animal model in cardiovascular research: feasibility and normal values.

Authors:  Sara Roldan Ramos; Guido Pieles; Wei Hui; Ryo Ishii; Cameron Slorach; Mark K Friedberg
Journal:  Int J Cardiovasc Imaging       Date:  2017-08-24       Impact factor: 2.357

2.  A Newborn with Infantile-Onset Pompe Disease Improving after Administration of Enzyme Replacement Therapy: Case Report.

Authors:  Meltem Bor; Ozkan Ilhan; Evren Gumus; Solmaz Ozkan; Meryem Karaca
Journal:  J Pediatr Intensive Care       Date:  2020-07-15

3.  Disproportionate cardiac hypertrophy during early postnatal development in infants born preterm.

Authors:  Christina Y L Aye; Adam J Lewandowski; Pablo Lamata; Ross Upton; Esther Davis; Eric O Ohuma; Yvonne Kenworthy; Henry Boardman; Samuel Wopperer; Alice Packham; Satish Adwani; Kenny McCormick; Aris T Papageorghiou; Paul Leeson
Journal:  Pediatr Res       Date:  2017-05-24       Impact factor: 3.756

4.  Reference Values for Point-of-Care Echocardiographic Measurements of Preterm Infants in China.

Authors:  Dan-Fang Lu; Xiao-Mei Tong; Yun-Feng Liu; Hua Zhang
Journal:  Front Pediatr       Date:  2022-06-30       Impact factor: 3.569

5.  Neonatal circulatory failure due to acute hypertensive crisis: clinical and echocardiographic clues.

Authors:  Jacoba Louw; Stephen Brown; Liesbeth Thewissen; Anne Smits; Benedicte Eyskens; Ruth Heying; Bjorn Cools; Elena Levtchenko; Karel Allegaert; Marc Gewillig
Journal:  Cardiovasc J Afr       Date:  2013-04       Impact factor: 1.167