Literature DB >> 21929609

Comparison of a rebound and an applanation tonometer for measuring intraocular pressure in normal rabbits.

Fabiana Quartiero Pereira1, Bernardo Stefano Bercht, Mírian Gomes Soares, Maurício Grillo Bittencourt da Mota, João Antonio Tadeu Pigatto.   

Abstract

OBJECTIVE: To compare intraocular pressure (IOP) measurements made on healthy adult rabbits without the effect of tranquilizers using the new applanation tonometer, Tono-Pen Avia(®), and the rebound tonometer Tonovet(®).
METHODS: Intraocular pressure was measured throughout the day (6:00, 9:00, 12:00, 15:00, and 18:00 h) in 38 adult New Zealand White rabbits (76 eyes). The animals were 20 males and 18 females, with a mean weight of 3.5 kg and an average age of 6 months. A complete ocular exam (including Schirmer tear test, fluorescein staining, slit-lamp biomicroscopy, and direct ophthalmoscopy) was performed on all animals at the beginning of the trial. Rebound tonometry was performed, and after 10 min, anesthetic drops were instilled and applanation tonometry was carried out. IOP values obtained using the two techniques were analyzed statistically.
RESULTS: The mean IOP was 9.51 ± 2.62 mmHg with Tonovet(®), and 15.44 ± 2.16 mmHg with the Tono-Pen Avia(®). Significant differences between measurements with the two tonometers were observed (P < 0.001). The linear regression equation describing the relationship between the two tonometers was y = 0.4923x + 10.754 (y = Tonovet(®) and x = Tono-Pen Avia(®)). High IOPs were recorded in the early measurements (6:00), but the average IOPs from both devices were statistically similar throughout the day (P = 0.086). The correlation coefficient was r(2) = 0.357. No significant difference in IOP regarding gender was observed.
CONCLUSION: The Tono-Pen Avia(®) recorded higher levels of IOP compared with the Tonovet(®). Early in the day, the IOP of rabbits was higher than later in the day, regardless of the tonometer used.
© 2011 American College of Veterinary Ophthalmologists.

Entities:  

Mesh:

Year:  2011        PMID: 21929609     DOI: 10.1111/j.1463-5224.2011.00879.x

Source DB:  PubMed          Journal:  Vet Ophthalmol        ISSN: 1463-5216            Impact factor:   1.644


  12 in total

1.  Applanation optical coherence elastography: noncontact measurement of intraocular pressure, corneal biomechanical properties, and corneal geometry with a single instrument.

Authors:  Manmohan Singh; Zhaolong Han; Achuth Nair; Alexander Schill; Michael D Twa; Kirill V Larin
Journal:  J Biomed Opt       Date:  2017-02-01       Impact factor: 3.170

2.  Targeted delivery of antiglaucoma drugs to the supraciliary space using microneedles.

Authors:  Yoo C Kim; Henry F Edelhauser; Mark R Prausnitz
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-09-11       Impact factor: 4.799

3.  Intraocular Pressure, Tear Production, and Ocular Echobiometry in Guinea Pigs (Cavia porcellus).

Authors:  Seyed Mehdi Rajaei; Maneli Ansari Mood; Reza Sadjadi; Farzaneh Azizi
Journal:  J Am Assoc Lab Anim Sci       Date:  2016       Impact factor: 1.232

4.  Preliminary study on retinal vascular and oxygen-related changes after long-term silicone oil and foldable capsular vitreous body tamponade.

Authors:  Wei Yang; Yongguang Yuan; Yao Zong; Zhen Huang; Shuyi Mai; Yujie Li; Xiaobing Qian; Yaqin Liu; Qianying Gao
Journal:  Sci Rep       Date:  2014-06-12       Impact factor: 4.379

5.  Repeatability, reproducibility and agreement of intraocular pressure measurement in rabbits by the TonoVet and Tono-Pen.

Authors:  Di Ma; Chong-Bo Chen; Jiajian Liang; Zhihao Lu; Haoyu Chen; Mingzhi Zhang
Journal:  Sci Rep       Date:  2016-10-12       Impact factor: 4.379

6.  Evaluation of Therapeutic Tissue Crosslinking (TXL) for Myopia Using Second Harmonic Generation Signal Microscopy in Rabbit Sclera.

Authors:  Mariya Zyablitskaya; Anna Takaoka; Emilia L Munteanu; Takayuki Nagasaki; Stephen L Trokel; David C Paik
Journal:  Invest Ophthalmol Vis Sci       Date:  2017-01-01       Impact factor: 4.799

7.  Evaluation of stability and biocompatibility of PHEMA-PMMA keratoprosthesis by penetrating keratoplasty in rabbits.

Authors:  Yawon Hwang; Gonhyung Kim
Journal:  Lab Anim Res       Date:  2016-12-23

8.  Comparison of two prototypes of a magnetically adjustable glaucoma implant in rabbits.

Authors:  Birthe Schwerk; Lisa Harder; Claudia Windhövel; Marion Hewicker-Trautwein; Anna Wagner; Jan-Peter Bach; Lena Carolin Voigt; Ulf Hinze; Boris Chichkov; Heinz Haferkamp; Holger Lubatschowski; Stephan Nikolic; Ingo Nolte
Journal:  PLoS One       Date:  2019-04-11       Impact factor: 3.240

9.  Intraocular pressure measurements using the TONOVET® rebound tonometer: Influence of the probe-cornea distance.

Authors:  Blanche D Rodrigues; Fabiano Montiani-Ferreira; Mariza Bortolini; André T Somma; András M Komáromy; Peterson Triches Dornbusch
Journal:  Vet Ophthalmol       Date:  2020-10-17       Impact factor: 1.644

10.  Antimicrobial Studies Using the Therapeutic Tissue Cross-Linking Agent, Sodium Hydroxymethylglycinate: Implication for Treating Infectious Keratitis.

Authors:  Patrick B Rapuano; Alexandra H Scanameo; Daeryl E Amponin; Sefy A Paulose; Mariya Zyablitskaya; Anna Takaoka; Leejee H Suh; Takayuki Nagasaki; Stephen L Trokel; David C Paik
Journal:  Invest Ophthalmol Vis Sci       Date:  2018-01-01       Impact factor: 4.799

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.