Literature DB >> 21928261

Long-term outcome of epi-LASIK for high myopia.

Shiyuan Wang1, Jinhui Dai, Renyuan Chu, Xingtao Zhou.   

Abstract

PURPOSE: To evaluate the long-term outcomes of epipolis laser-assisted in situ keratomileusis (epi-LASIK) for high myopia.
METHODS: High myopic patients who underwent epi-LASIK during 2004 and 2005 were included in this study. Epi-LASIK was performed with an automatically rotational epikeratome (KM-5000D). Postoperative visual acuity, manifest refraction, and haze formation were assessed 3 mo, 6 mo, 1 y, and 3 y after surgery. Results were compared by dividing patients into 2 groups according to preoperative mean refractive spherical equivalent (MRSE): group A (≥-6 D to -10 D; group B ≥-10 D). The differences within groups were analyzed using mixed model for continuous variables. The differences between groups were analyzed using t test or rank sum test for continuous variables, and Pearson χ² or Fisher exact probabilities for categorical variables.
RESULTS: A total of 20 patients (33 eyes) were followed up for more than 3 years with 17 eyes in group A (MRSE -8.15 ± 1.41 D) and 16 eyes in group B (MRSE -12.95 ± 2.91 D). While postoperative refraction regression occurred in both groups, it was more prominent in group B (p<0.05). The long-term predictability is good in group A with 14 eyes (82.35%) within ±1 D of attempted correction at 3 years while the percentage in group B was 18.75%. The efficacy index was significantly different between the 2 groups (p<0.05): 0.84 ± 0.29 for group A and 0.61 ± 0.47 for group B at 3 years. The safety index was above 1.0 at each timepoint in both groups. Haze was at low level and faded with time after epi-LASIK.
CONCLUSIONS: Epi-LASIK had a satisfactory long-term effect for high myopia of less than -10 D. Myopic regression limited the satisfaction of epi-LASIK in eyes with myopia of more than -10.0 D.

Entities:  

Mesh:

Year:  2012        PMID: 21928261     DOI: 10.5301/ejo.5000025

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  2 in total

1.  Influence of transient intraocular pressure elevation during laser in situ keratomileusis on rabbit retina thickness.

Authors:  Hai-Xia Zhao; Hui Liu; Chun-Mei Niu; Wen-Ying Guan
Journal:  Int J Ophthalmol       Date:  2015-12-18       Impact factor: 1.779

2.  Implantable collamer lens versus small incision lenticule extraction for high myopia correction: A systematic review and meta-analysis.

Authors:  Kai Cao; Jingshang Zhang; Jinda Wang; Mayinuer Yusufu; Shanshan Jin; Shuying Chen; Ningli Wang; Zi-Bing Jin; Xiu Hua Wan
Journal:  BMC Ophthalmol       Date:  2021-12-27       Impact factor: 2.209

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.