Ultrasound-guided percutaneous tenotomy of the long head of the biceps tendon: a non-reliable technique.

Bruno Lévy1, Alexandre Ducat, Pascal Gaudin, Ali Maqdés, Jean Louis Brasseur, Shahnaz Klouche, Philippe Hardy.   

Abstract

PURPOSE: To evaluate the feasibility of ultrasound-guided percutaneous tenotomy of the long head of the biceps tendon via a keyhole incision.
METHODS: This was an anatomical study performed on twelve embalmed cadaveric shoulder joints. The rotator cuff and the position of the long head of the biceps tendon were explored by ultrasound prior to beginning the procedure. The biceps tenotomy was performed under ultrasound guidance by a highly experienced sonographer who was trained in shoulder tendon exploration. Arthroscopic exploration of the shoulder was performed immediately after the percutaneous biceps tenotomy to assess the quality and the location of the biceps tenotomy.
RESULTS: Three out of twelve tendons (25%) were completely sectioned at the level of the glenoid insertion. More seriously, iatrogenic lesions of the cartilage of the humeral head, the supraspinatus tendon and the subscapularis tendon were observed.
CONCLUSION: This study shows that ultrasound-guided percutaneous tenotomy of the long head of the biceps tendon is not reliable.

Entities:  

Mesh:

Year:  2011        PMID: 21927953     DOI: 10.1007/s00167-011-1671-1

Source DB:  PubMed          Journal:  Knee Surg Sports Traumatol Arthrosc        ISSN: 0942-2056            Impact factor:   4.342


  9 in total

1.  [Clinical results of arthroscopic tenotomy of the long head of the biceps brachii in full thickness tears of the rotator cuff without repair: 40 cases].

Authors:  C Maynou; N Mehdi; X Cassagnaud; S Audebert; H Mestdagh
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2005-06

2.  [The long head of the biceps].

Authors:  G Walch
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2005-12

Review 3.  Biceps tenotomy versus tenodesis: a review of clinical outcomes and biomechanical results.

Authors:  Andrew R Hsu; Neil S Ghodadra; Matthew T Provencher; Paul B Lewis; Bernard R Bach
Journal:  J Shoulder Elbow Surg       Date:  2010-11-04       Impact factor: 3.019

4.  Anatomic relationships in the shoulder impingement syndrome.

Authors:  W C Burns; T L Whipple
Journal:  Clin Orthop Relat Res       Date:  1993-09       Impact factor: 4.176

5.  Patient-related factors and complications after arthroscopic tenotomy of the long head of the biceps tendon.

Authors:  Tae Kang Lim; Eun Sun Moon; Kyoung Hwan Koh; Jae Chul Yoo
Journal:  Am J Sports Med       Date:  2011-01-06       Impact factor: 6.202

6.  Dynamic ultrasound assessment in the diagnosis of intra-articular entrapment of the biceps tendon (hourglass biceps): A preliminary investigation.

Authors:  N Pujol; R Hargunani; S Gadikoppula; B Holloway; P M Ahrens
Journal:  Int J Shoulder Surg       Date:  2009-10

7.  The four-in-one arthroplasty for the painful arc syndrome.

Authors:  T J Neviaser; R J Neviaser; J S Neviaser; J S Neviaser
Journal:  Clin Orthop Relat Res       Date:  1982-03       Impact factor: 4.176

8.  [Entrapment of the long head of the biceps: the "hourglass biceps". Another cause of pain and locking of the shoulder].

Authors:  P Boileau; P-M Ahrens; C Trojani; J-S Coste; B Cordéro; P Rousseau
Journal:  Rev Chir Orthop Reparatrice Appar Mot       Date:  2003-12

Review 9.  The proximal biceps as a pain generator and results of tenotomy.

Authors:  Istvan Szabó; Pascal Boileau; Gilles Walch
Journal:  Sports Med Arthrosc Rev       Date:  2008-09       Impact factor: 1.985

  9 in total
  7 in total

1.  Ultrasound-guided percutaneous long head of the biceps tenotomy.

Authors:  Sim Sai Tin; Viroj Wiwanitkit
Journal:  HSS J       Date:  2015-02-03

2.  Reply to letter to the editor: ultrasound-guided percutaneous long head of the biceps tenotomy.

Authors:  Harry G Greditzer; Jean Jose
Journal:  HSS J       Date:  2015-01-30

3.  Ultrasound-guided percutaneous long head of the biceps tenotomy: a novel technique with case report.

Authors:  Harry G Greditzer; Lee D Kaplan; Bryson P Lesniak; Jean Jose
Journal:  HSS J       Date:  2014-07-25

4.  Clinical indications for image-guided interventional procedures in the musculoskeletal system: a Delphi-based consensus paper from the European Society of Musculoskeletal Radiology (ESSR)-part I, shoulder.

Authors:  Luca Maria Sconfienza; Miraude Adriaensen; Domenico Albano; Georgina Allen; Maria Pilar Aparisi Gómez; Alberto Bazzocchi; Ian Beggs; Bianca Bignotti; Vito Chianca; Angelo Corazza; Danoob Dalili; Miriam De Dea; Jose Luis Del Cura; Francesco Di Pietto; Eleni Drakonaki; Fernando Facal de Castro; Dimitrios Filippiadis; Jan Gielen; Salvatore Gitto; Harun Gupta; Andrea S Klauser; Radhesh Lalam; Silvia Martin; Carlo Martinoli; Giovanni Mauri; Catherine McCarthy; Eugene McNally; Kalliopi Melaki; Carmelo Messina; Rebeca Mirón Mombiela; Benedikt Neubauer; Cyprian Olchowy; Davide Orlandi; Athena Plagou; Raquel Prada Gonzalez; Saulius Rutkauskas; Ziga Snoj; Alberto Stefano Tagliafico; Alexander Talaska; Violeta Vasilevska-Nikodinovska; Jelena Vucetic; David Wilson; Federico Zaottini; Marcello Zappia; Marina Obradov
Journal:  Eur Radiol       Date:  2019-09-16       Impact factor: 5.315

5.  In-office shoulder arthroscopy and tenotomy of the long head of the biceps tendon-a cadaveric feasibility study.

Authors:  Ion-Andrei Popescu; Frédéric Teboul; Jean-Nöel Goubier; Amir Ghazanfari
Journal:  Int Orthop       Date:  2019-08-01       Impact factor: 3.075

6.  Ultrasound-guided intra-articular tenotomy of the long head of the biceps: a cadaveric feasibility study.

Authors:  Frank Atlan; Jean David Werthel
Journal:  Int Orthop       Date:  2016-06-04       Impact factor: 3.075

7.  In-Office Biceps Tenotomy with Needle Arthroscopy: A Feasibility Study.

Authors:  Marc-Olivier Gauci; Brieuc Monin; Alexandre Rudel; Laurent Blasco; Bastien Bige; Pascal Boileau
Journal:  Arthrosc Tech       Date:  2021-04-12
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.