Literature DB >> 21926357

Combining dissimilar metals in orthopaedic implants: revisited.

Kevin C Zartman1, Gregory C Berlet, Christopher F Hyer, Joseph R Woodard.   

Abstract

The use of metals as implant materials has become common practice in the field of orthopaedics. A wide variety of conditions are treated with metallic implants, and designers have used an assortment of materials to meet the unique mechanical demands of each application. The majority of implants used today, whether pins, plates, screws, or total joints, are made of cobalt-chrome alloy, stainless steel, or titanium. Common metallurgic wisdom cautions against bonding dissimilar metals in a biologically active environment. Surgeons have therefore shied away from combining dissimilar metal implants because of the fear of inciting corrosion that could potentially compromise the implants and lead to aseptic loosening, implant failure, or adverse biological reaction in host tissue. As surgical reconstruction and arthroplasty options expand with the advent of newer implants and expanded operative techniques, the orthopaedic surgeon will increasingly be faced with weighing the risks and benefits of combining implants made of dissimilar metals in a patient. Here, the authors examine the origins of the concern over using mixed metals, discuss mechanisms of corrosion as they relate to surgical implants, and review both in vitro and in vivo studies concerning the most common combinations of dissimilar metals in order to guide the surgeon in choosing implants.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21926357     DOI: 10.1177/1938640011422597

Source DB:  PubMed          Journal:  Foot Ankle Spec        ISSN: 1938-6400


  3 in total

1.  Peri-implant fracture of the distal tibia after intra-medullary nailing of a tibial fracture: a report of two cases.

Authors:  Varatharaj Mounasamy; Pingal Desai
Journal:  Eur J Orthop Surg Traumatol       Date:  2012-08-11

2.  Enhanced biocompatibility and osseointegration of calcium titanate coating on titanium screws in rabbit femur.

Authors:  Zi-Li Wang; Rong-Zhen He; Bin Tu; Xu Cao; Jin-Shen He; Han-Song Xia; Chi Liang; Min Zou; Song Wu; Zhen-Jun Wu; Kun Xiong
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2017-06-06

3.  A systematic review of metal ion concentrations following instrumented spinal fusion.

Authors:  Omar Siddiqi; Jennifer C Urquhart; Parham Rasoulinejad
Journal:  Spine Deform       Date:  2020-08-11
  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.