Literature DB >> 21924650

Is the diagnostic yield of prostate needle biopsies affected by prostate volume?

Dan Leibovici1, Yaniv Shilo, Orit Raz, Kobi Stav, Judith Sandbank, Michael Segal, Amnon Zisman.   

Abstract

OBJECTIVES: To determine the effect of prostate volume on the diagnostic yield of prostate biopsies.
MATERIALS AND METHODS: 155 consecutive patients underwent 12-core transrectal ultrasound guided needle biopsies. Data were collected prospectively on age, serum PSA, digital rectal examination (DRE), previous prostate biopsies, prostate volume and pathologic result. Univariate and multivariate logistic regressions were undertaken to determine the effect of prostate volume on the risk for a positive biopsy.
RESULTS: 45 patients (29%) were diagnosed with cancer. The median patient age was 63 (range 48-82) years, the median PSA level was 6.7 ng/ml (0.5-156 ng/ml), and the median prostate volume was 57 ml (16-273 ml). 42 patients (27%) had an abnormal DRE and 51 (33%) had undergone previous prostate biopsies. Positive biopsy rates were 39%, 33%, and 14% for prostate volume below 46 ml, between 45 and 73 ml, and above 72 ml, respectively. Univariate analysis showed that age, serum PSA, DRE and prostate volume were all associated with a positive biopsy. Multivariate analysis adjusted for age, PSA and DRE showed a significant risk increase for a positive biopsy in smaller prostates. (OR = 5.6 95% CI 1.75-17.89; and 8.86 95% CI 2.72-28.82, for prostate volume between 45 and 72 ml and below 45 ml, respectively).
CONCLUSION: The diagnostic yield of prostate biopsies is significantly lower in large prostates. As the result the standard 12-core biopsy may be insufficient for the diagnosis of cancer in large prostates.
Copyright © 2013 Elsevier Inc. All rights reserved.

Entities:  

Keywords:  Biopsy; Diagnostic yield; Large prostates; Prostate volume

Mesh:

Substances:

Year:  2011        PMID: 21924650     DOI: 10.1016/j.urolonc.2011.08.008

Source DB:  PubMed          Journal:  Urol Oncol        ISSN: 1078-1439            Impact factor:   3.498


  3 in total

1.  How reliable is 12-core prostate biopsy procedure in the detection of prostate cancer?

Authors:  Ege Can Serefoglu; Serkan Altinova; Nevzat Serdar Ugras; Egemen Akincioglu; Erem Asil; M Derya Balbay
Journal:  Can Urol Assoc J       Date:  2013-05-13       Impact factor: 1.862

2.  TRUS Biopsy Yield in Indian Population: A Retrospective Analysis.

Authors:  Sunil Raghunath Patil; Prakash Wamanrao Pawar; Ajit Somaji Sawant; Akshay Vijay Patil; Sayalee Suryabhan Narwade; Shankar Tanaji Mundhe; Abhishek Jaysukhbhai Savalia; Ashwin Sunil Tamhankar
Journal:  J Clin Diagn Res       Date:  2017-02-01

3.  Effect of prostate volume on the peripheral nerve block anesthesia in the prostate biopsy: A strobe-compliant study.

Authors:  Yang Luan; Tian-Bao Huang; Xiao Gu; Guang-Chen Zhou; Sheng-Ming Lu; Hua-Zhi Tao; Bi-De Liu; Xue-Fei Ding
Journal:  Medicine (Baltimore)       Date:  2016-07       Impact factor: 1.889

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.