Literature DB >> 21924199

Torsional resistance of retreatment instruments.

Hélio P Lopes1, Carlos N Elias, Gislaine A F Vedovello, Carlos E S Bueno, Marcelo Mangelli, José F Siqueira.   

Abstract

INTRODUCTION: This study compared the torsional resistance of two brands of rotary nickel-titanium (NiTi) instruments indicated for endodontic retreatment.
METHODS: Mtwo retreatment instruments #15 and #25 (VDW, Munich, Germany) and ProTaper Universal retreatment instruments D2 and D3 (Maillefer/Dentsply, Ballaigues, Switzerland) were subjected to a torsional assay in clockwise rotation. The two parameters evaluated were maximum torque and angular deflection at failure. Fractured instruments had their fractured surfaces and helical shafts examined by scanning electron microscopy.
RESULTS: The results indicated that the angular deflection at fracture decreased in the following order: Mtwo retreatment file #15 > Mtwo retreatment file #25 > ProTaper Universal retreatment file D2 > ProTaper Universal retreatment file D3. As for the maximum torque values, the results revealed the following descending order: ProTaper Universal file D2 > Mtwo retreatment file #25 > ProTaper Universal file D3 > Mtwo retreatment file #15. Scanning electron microscopic analysis revealed that plastic deformation occurred along the helical shaft of the fractured instruments. Fractured surfaces were of the ductile type.
CONCLUSIONS: The instruments tested showed different torsional behavior depending on the parameter evaluated. If one considers that high angular deflection values may serve as a safety factor, then the Mtwo retreatment instruments showed significantly better results.
Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21924199     DOI: 10.1016/j.joen.2011.06.004

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  4 in total

1.  Surface deformation of several nickel-titanium rotary instruments after removal of the root canal filling materials: a scanning electron microscope evaluation.

Authors:  Taha Özyürek; Ebru Özsezer Demiryürek
Journal:  Odontology       Date:  2019-09-17       Impact factor: 2.634

2.  Apical transportation using Mtwo or Reciproc retreatment systems in severely curved canals: a micro-computed tomographic study.

Authors:  Isabelle L L Gomes; Flávio R F Alves; Marília F Marceliano-Alves; Stephanie B Silveira; Júlio Cézar N Sousa; José Claudio Provenzano; Lucio Souza Gonçalves
Journal:  Clin Oral Investig       Date:  2022-10-20       Impact factor: 3.606

3.  Effects of aspirin-loaded graphene oxide coating of a titanium surface on proliferation and osteogenic differentiation of MC3T3-E1 cells.

Authors:  Liping Ren; Shuang Pan; Haiqing Li; Yanping Li; Lina He; Shuang Zhang; Jingyi Che; Yumei Niu
Journal:  Sci Rep       Date:  2018-10-11       Impact factor: 4.379

4.  Evaluation of Torsional Resistance and Bending Stiffness of Coronal Flaring Nickel-Titanium Instruments.

Authors:  Theodoro Weissheimer; Murilo Alcalde; Julia Barrionuevo Cortez; Ricardo Rosa; Rodrigo Vivan; Pedro Henrique Souza Calefi; Marco Antonio Hungaro Duarte; Marcus Vinicius So
Journal:  Eur Endod J       Date:  2021-12
  4 in total