Literature DB >> 21924190

Investigation on the shaping ability of nickel-titanium files when used with a reciprocating motion.

Vittorio Franco1, Cristiano Fabiani, Silvio Taschieri, Augusto Malentacca, Monica Bortolin, Massimo Del Fabbro.   

Abstract

INTRODUCTION: The introduction of nickel-titanium (NiTi) files into clinical practice has improved the quality of canal shaping, but increasing the curvature of the root canal (or the diameter of the master instrument that prepares the full working length) could result in more transportation, straightening, and aberration of the canal. Nickel-titanium instruments are significantly safer and have an extended cyclic fatigue life when used with a reciprocating movement. The purpose of this study was to compare the shaping ability of FlexMaster NiTi instruments when used in either continuous or reciprocating movements.
METHODS: Thirty-two Endo Training Blocks ISO 15, 2% taper, 10-mm radius of curvature, and 70° angle of curvature were prepared, according to the group, with FlexMaster NiTi instruments either in continuous rotation or in reciprocating (60° clockwise, 40° counterclockwise) movement. Preoperative and postoperative images of the simulated canals were taken under standardized conditions. The preoperative and postoperative images were combined exactly. The amount of resin removed was determined both for the inner (convex) and the outer (concave) sides of the curvature at 10 different points.
RESULTS: In the most apical third of the canal, the Continuous group produced the largest enlargement of the canal as compared with the Reciprocating group (P < .05). In the apical third, the Continuous group displayed significantly greater enlargement of the canal at the external side.
CONCLUSIONS: The shaping of simulated canals is more centered by using a reciprocating motion when compared with continuous rotation, but the reciprocating motion could be more time-consuming.
Copyright © 2011 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21924190     DOI: 10.1016/j.joen.2011.06.030

Source DB:  PubMed          Journal:  J Endod        ISSN: 0099-2399            Impact factor:   4.171


  30 in total

1.  ProTaper and WaveOne systems three-dimensional comparison of device parameters after the shaping technique. A micro-CT study on simulated root canals.

Authors:  Mario Dioguardi; Giuseppe Troiano; Luigi Laino; Lucio Lo Russo; Giovanni Giannatempo; Floriana Lauritano; Marco Cicciù; Lorenzo Lo Muzio
Journal:  Int J Clin Exp Med       Date:  2015-10-15

2.  "Dentinal microcracks after root canal preparation" a comparative evaluation with hand, rotary and reciprocating instrumentation.

Authors:  N Tulasi Priya; Veeramachaneni Chandrasekhar; S Anita; Muralidhar Tummala; T B Phanindhar Raj; Vijetha Badami; Pradeep Kumar; E Soujanya
Journal:  J Clin Diagn Res       Date:  2014-12-05

3.  Shaping ability of a new heat-treated NiTi system in continuous rotation or reciprocation in artificial curved canals.

Authors:  Jad Rebeiz; Claire El Hachem; Nada El Osta; Marc Habib; Tamara Rebeiz; Carla Zogheib; Marc Krikor Kaloustian
Journal:  Odontology       Date:  2021-03-22       Impact factor: 2.634

4.  Metallurgical analysis and fatigue resistance of WaveOne and ProTaper nickel-titanium instruments.

Authors:  Chiara Pirani; Oddone Ruggeri; Pier Paolo Cirulli; Gian Andrea Pelliccioni; Maria Giovanna Gandolfi; Carlo Prati
Journal:  Odontology       Date:  2013-04-09       Impact factor: 2.634

5.  Effects of continuous chelation on the instrumentation of curved canals with a martensitic NiTi file system: an ex vivo micro-CT evaluation.

Authors:  M Sobrino; F Foschi; R Estévez; G Loroño; A Conde Villar; R Pérez-Alfayate
Journal:  Odontology       Date:  2022-07-07       Impact factor: 2.634

6.  Comparison of the cyclic fatigue resistance of One Curve, F6 Skytaper, Protaper Next, and Hyflex CM endodontic files.

Authors:  Charlotte Gouédard; Laurent Pino; Reza Arbab-Chirani; Shabnam Arbab-Chirani; Valérie Chevalier
Journal:  Restor Dent Endod       Date:  2022-03-04

7.  The effects of different nickel-titanium instruments on dentinal microcrack formations during root canal preparation.

Authors:  Yakup Ustun; Tugrul Aslan; Burak Sagsen; Bertan Kesim
Journal:  Eur J Dent       Date:  2015 Jan-Mar

8.  Self-adjusting file (SAF) separation in clinical use: A preliminary survey among experienced SAF users regarding prevalence and retrieval methods.

Authors:  Michael Solomonov; Joe Ben-Itzhak; Anda Kfir; Oscar von Stetten; Elena Lipatova; Eleftherios T Farmakis
Journal:  J Conserv Dent       Date:  2015 May-Jun

9.  Cyclic fatigue resistance of OneShape, Reciproc, and WaveOne: An in vitro comparative study.

Authors:  Alberto Dagna; Claudio Poggio; Riccardo Beltrami; Marco Colombo; Marco Chiesa; Stefano Bianchi
Journal:  J Conserv Dent       Date:  2014-05

10.  Canal transportation and centering ability of twisted file and reciproc: a cone-beam computed tomography assessment.

Authors:  Kiumars Nazari Moghadam; Shahriar Shahab; Golriz Rostami
Journal:  Iran Endod J       Date:  2014-07-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.