Literature DB >> 21922951

Commissioning of a displacement-controlled knee wear simulator and exploration of some issues related to the lubricant.

J-M Brandt1, K D J Charron, L Zhao, S J MacDonald, J B Medley.   

Abstract

A six-station displacement-controlled knee simulator with separately controlled left (L) and right (R) banks (three wear implants per bank) was commissioned for a total of three million cycles (Mc) following ISO 14243-3. A commissioning protocol was applied to compare the polyethylene wear among the six wear stations by exchanging the implants between wear stations. Changes in lubricant characteristics during wear testing, such as polypeptide degradation, low-molecular-weight polypeptide concentration, and possible microbial contamination were also assessed. The total mean wear rate for the implants was 23.60 +/- 1.96 mm3/Mc and this was of a similar magnitude to the mean wear rate for the same implant tested under similar conditions by DePuy Orthopaedics Inc. (Warsaw, IN). Repeated run-in wear was observed when the implants were exchanged between wear stations, suggesting that implants should be subjected to the same wear station throughout the duration of a wear test. The total polypeptide degradation for the implants measured 30.53 +/- 3.96 percent; the low-molecular-weight polypeptide concentration of the "used" lubricant for implants (0.131 +/- 0.012 g/L) was 3.3 times greater than the mean polypeptide concentration of the fresh, "unused" lubricant (0.039 +/- 0.004 g/L). This increase in low-molecular weight polypeptide concentration was suggested to be attributable to protein shear in the articulation of the implant, the circulation of the lubricant, and some proteolytic activity. Sodium azide was ineffective in maintaining a sterile environment for wear testing as a single, highly motile Gram-negative micro-organism was identified in the lubricant from wear tests.

Entities:  

Mesh:

Substances:

Year:  2011        PMID: 21922951     DOI: 10.1177/0954411911406061

Source DB:  PubMed          Journal:  Proc Inst Mech Eng H        ISSN: 0954-4119            Impact factor:   1.617


  4 in total

1.  The choice of the femoral center of rotation affects material loss in total knee replacement wear testing - A parametric finite element study of ISO 14243-3.

Authors:  Steven P Mell; Markus A Wimmer; Hannah J Lundberg
Journal:  J Biomech       Date:  2019-03-23       Impact factor: 2.712

2.  How do gait frequency and serum-replacement interval affect polyethylene wear in knee-wear simulator tests?

Authors:  Jörn Reinders; Robert Sonntag; Jan Philippe Kretzer
Journal:  J Mater Sci Mater Med       Date:  2014-07-12       Impact factor: 3.896

3.  CR TKA UHMWPE wear tested after artificial aging of the vitamin E treated gliding component by simulating daily patient activities.

Authors:  Jens Schwiesau; Bernhard Fritz; Ines Kutzner; Georg Bergmann; Thomas M Grupp
Journal:  Biomed Res Int       Date:  2014-11-20       Impact factor: 3.411

4.  A comparison between electromechanical and pneumatic-controlled knee simulators for the investigation of wear of total knee replacements.

Authors:  Abdellatif Abdelgaied; John Fisher; Louise M Jennings
Journal:  Proc Inst Mech Eng H       Date:  2017-03-25       Impact factor: 1.617

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.